USE

Button
Function
L
Turns the lighting system on and off.
Press and hold for approx. 2 seconds to turn the
lighting system on and off at reduced intensity.
T1
Turn the suction motor on and off at speed one.
Press and hold the button for approximately 2
seconds, with all the loads turned off (Motor and
Lights), to reset the Filters and turn off the Leds that
are lit.
T2
Turn the suction motor on at speed two.
T3
Turn the suction motor on at speed three.
Press and hold the button for 2 seconds to activate
intensive speed. This speed is timed to run for 6
minutes. At the end of this time the system will
automatically return to the speed set before.
T4
Press and hold the button for approximately 2
seconds to activate automatic shutdown with a 30'
delay (Motor+Lights).
Press and hold for approximately 5 seconds to
enable/disable the Activated Charcoal Filter alarm.
EN
L
T1
L1
T2
L2
T3
L3
T4
L4
Control panel
Led
-
-
On.
After 100 working hours all the
LEDs (L1-L2-L3-L4) will light up
and remain lit to indicate saturation
of the metal grease filters.
After 200 working hours all the
LEDs (L1-L2-L3-L4) will light up
and start to flash to indicate
saturation of the activated charcoal
filters.
On.
On.
On.
2 Flashes of the Leds (L1-L2-L3)
Filter Alarm Enabled.
1 Flash of the Leds (L1-L2-L3)
Filter Alarm Disabled.