4-20 Compaq Deskpro Workstation AP250 Maintenance and Service Guide

Memory Problems

SCSI Problems

Writer: Bruce Sullivan Project: Compaq Deskpro Workstation AP250 Maintenance and Service Guide Comments:
Part Number: 118133-001 File Name: e-ch4 Diagnostic Tools.doc Last Saved On: 10/26/99 3:09 PM
Problem
Out of memory error.
Memory count during POST is wrong.
Insufficient memory error during operation.
Problem
System will not boot from a
SCSI drive.
Compaq Confidential – Need to Know Required
Table 4-9
Memory Problems
Possible Solution
Run Performance Monitor. Click Start ,
Programs , Administrative Tools .
The workstation has run out of memory to
run the application. Check the application
documentation to determine memory
requirements.
The Direct RIMMs may not be installed
correctly. Verify that the Direct RIMMs have
been installed correctly in the RIMM
sockets then run the Computer Setup
utility.
The system has run out of memory for the
application. Check memory requirements
for the application or install additional
memory.
Table 4-10
SCSI Problems
Cause
The SCSI drive is not
configured correctly.
Solution
Be sure that the drive
cabling and jumpers are
set correctly. To boot a
SCSI drive, the drive ID
number must be set to 0.

Advertisement