LFA VM Lab Mixer User Manual page 21

Table of Contents

Advertisement

Lubrication Schedule
LFA recommends the following VM
following frequency:
Part
Bushing on Main Cam
Drive Shaft
Gearbox
Lab Mixer parts to be lubricated according to the
®
Location
Bushing that
connects the
Hopper to
the VM
®
Lab
Mixer's base
Inside the VM
®
Lab Mixer's
base and above
the Motor.
Image
Apply grease in the
following situations:
1) After every 100
hours of use, 2) after
a deep clean, or 3)
if returning to use
the machine after a
prolonged period of
time.
Check the oil
inspection window
every month and top
up if required.
Type of
Frequency
Lubricant
NLGI
Grade 2
H2 for
food
product
460
Grade
Worm
Gear Oil
21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VM Lab Mixer and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Vm lab mixer 2Vm lab mixer 10Vm lab mixer 15

Table of Contents