3. Wiring figure

4-core shielding wire
• Connect the female joint of the wires group from the mainboard with the male joint
of the connective wires group. (See Fig. 3-3)
• Connect the other side of the connective wires group with the male joint of the
wires group leads from the wire controller. (See Fig. 3-3)
4. Wire controller upper part Remove
• Insert a flat screwdriver into the slots in the
lower part of the wire controller (2 places).
• Remove the upper part of the wire controller
(Fig. 3-4)
NOTE: The PCB is mounted in the upper part of the
wired controller. Be careful not to damage the board
with the screwdriver.
5. Fasten the wire controller back plate
• For surface mounting, fasten the back plate on the wall with the 3 screws (M4x20)
and plugs. (Fig. 3-5)
Screws (M4×20)
30 /
The connection
cable
Back plate
Mainboard
CN40
Fig. 3-3
Slots
Fig. 3-4
Fig. 3-5