Mitsubishi Electric MR-J5-B User Manual page 29

Hide thumbs Also See for MR-J5-B:
Table of Contents

Advertisement

I/O, monitor
Functions
Detailed functions
DI/DO
Output signal selection (device
setting)
Output signal (DO) forced output
A/B/Z-phase output
LED
Status display
Analog input/output
Analog monitor
Monitor
Power monitoring function
*1 "Ver." indicates the supported firmware version of the servo amplifier. The functions are available on servo amplifiers with the indicated
firmware version or later.
Option
Functions
Detailed functions
Regenerative
Simple converter
capacity
enhancement
Regenerative option
Multifunction regeneration
converter
*1 "Ver." indicates the supported firmware version of the servo amplifier. The functions are available on servo amplifiers with the indicated
firmware version or later.
Engineering tool
Functions
Detailed functions
Setup software
MR Configurator2
*1 "Ver." indicates the supported firmware version of the servo amplifier. The functions are available on servo amplifiers with the indicated
firmware version or later.
Description
This function assigns output devices such as
MBR (Electromagnetic brake interlock) to
certain pins of the connector.
This function forcibly switches the output
signals on and off regardless of the servo
status. Use this function for purposes such as
checking output signal wiring.
This function outputs the positions of the
encoder and linear encoder in the A/B/Z-phase
signal.
This function shows the servo status on the 7-
segment LED display.
This function outputs the servo status in voltage
in real time.
This function calculates the running power and
the regenerative power from the data in the
servo amplifier such as speed and current. The
power consumption and other values are
displayed on MR Configurator2.
Description
This function enables servo amplifiers to be
used in a common DC bus connection. Utilizing
the regenerative power contributes to energy-
conservation. In addition, it decreases the
number of molded case circuit breakers and
magnetic contactors.
Use this function if the built-in regenerative
resistor of the servo amplifier does not have
sufficient regenerative capacity for the
generated regenerative power.
This function returns the regenerative energy
generated at servo motor deceleration to the
power supply. The bus voltage can be
standardized among multiple servo amplifiers.
Description
This function performs settings such as servo
parameter settings, test operation, and
monitoring with a personal computer.
*1
Ver.
Detailed explanation
C4
Refer to "Assigning I/O devices" in
the following manual.
MR-J5 User's Manual (Function)
Page 60 Output signal (DO)
C4
forced output
C4
Refer to "A/B/Z-phase pulse output
function" in the following manual.
MR-J5 User's Manual (Function)
Page 35 Switch setting and
C4
display of the servo amplifier
C4
Refer to "MONITORING" in the
following manual.
MR-J5 User's Manual (Function)
C4
*1
Ver.
Detailed explanation
C4
Refer to "MR-CM simple converter"
in the following manual.
MR-J5 User's Manual
(Hardware)
C4
Refer to "Regenerative option" in the
following manual.
MR-J5 User's Manual
(Hardware)
C4
Refer to "FR-XC-(H) multifunction
regeneration converter" in the
following manual.
MR-J5 User's Manual
(Hardware)
*1
Ver.
Detailed explanation
Page 45 STARTUP
C4
2 FUNCTION
2.1 Function list
2