Mitsubishi Electric MR-J5-B User Manual page 13

Hide thumbs Also See for MR-J5-B:
Table of Contents

Advertisement

Model: MR-J5-
Satisfied standards
CE marking
UKCA marking
UL standard
Structure (IP rating)
*2
Close mounting
3-phase power supply
input
1-phase power supply
input
Mass [kg]
*1 This value is applicable when all I/O signals are used. Reducing the number of I/O points decreases the current capacity.
*2 If closely mounting the servo amplifiers, operate them at an ambient temperature of 0 ˚C to 45 ˚C or at 75 % or less of the effective load
ratio.
*3 This current value is applicable when a 3-phase power supply is used.
*4 If using 1-phase power supply in combination with the servo motor of 750 W or higher, operate the servo amplifier at 75 % or less of the
effective load ratio.
*5 This does not apply to connectors.
*6 The communication cycle depends on the controller specifications and the number of the connected axes.
400 V class
Model: MR-J5-
Output
Voltage
Rated current [A]
Main circuit power
Voltage/
supply input
Frequency
Rated current [A]
Permissible
voltage
fluctuation
Permissible frequency
fluctuation
Power supply capacity
[kVA]
Inrush current [A]
Control circuit power
Voltage/
supply input
Frequency
Rated current [A]
Permissible
voltage
fluctuation
Permissible frequency
fluctuation
Power consumption [W]
Inrush current [A]
Interface power supply
Voltage
Current capacity [A]
Control method
Dynamic brake
SSCNET III/H
Communication cycle
Communication
USB
function
Encoder output pulses
Analog monitor
Fully closed loop control
Scale measurement function
10B
20B
40B
LVD: EN 61800-5-1, EMC: EN 61800-3, MD: EN ISO 13849-1:2015, EN 61800-5-2, EN 62061
LVD: BS EN 61800-5-1, EMC: BS EN IEC 61800-3, MD: BS EN ISO 13849-1:2015, BS EN 61800-5-2,
BS EN 62061
UL 61800-5-1
Natural cooling, open (IP20)
Possible
Possible
0.8
60B4
3-phase 0 V AC to 480 V AC
1.6
At AC
3-phase 380 V AC to 480 V AC, 50 Hz/60 Hz
input
1.4
At AC
3-phase 323 V AC to 528 V AC
input
Within ±5 %
Refer to "Power supply capacity and generated loss" in the following manual.
MR-J5 User's Manual (Hardware)
Refer to "Inrush currents at power-on of main circuit and control circuit" in the following manual.
MR-J5 User's Manual (Hardware)
At AC
1-phase 380 V AC to 480 V AC, 50 Hz/60 Hz
input
0.1
At AC
1-phase 323 V AC to 528 V AC
input
Within ±5 %
30
Refer to "Inrush currents at power-on of main circuit and control circuit" in the following manual.
MR-J5 User's Manual (Hardware)
24 V DC ±10 %
0.3 (including CN8 connector signals)
Sine-wave PWM control, current control method
Built-in
*2
0.222 ms, 0.444 ms, 0.888 ms
Connection to a personal computer or other devices (MR Configurator2-compatible)
Compatible (A/B/Z-phase pulse)
Two channels
Supported
Supported
60B
70B
100B
Force cooling, open (IP20)
Impossible
1.0
1.4
100B4
200B4
2.8
5.5
2.5
5.1
*1
1.4 Servo amplifier standard specifications
200B
350B
500B
700B
Force cooling,
*5
open (IP20)
2.2
3.7
6.2
350B4
8.6
7.9
1 SPECIFICATIONS