Event
The wheelchair does not start.
The wheelchair cannot be charged.
The wheelchair cannot be driven.
Possible cause
The batteries are discharged.
The cable connection to the control panel
has come loose.
The main circuit breaker is turned off.
The main circuit breaker has tripped.
The main circuit breaker is turned off.
The charging circuit breaker has tripped.
The battery charger is connected.
The wheelchair is in freewheel mode.
The wheelchair is locked.
A seat function has triggered the
automatic drive inhibit.
The motors have gotten too warm.
Remedy
Charge the batteries.
Insert the cable in the control panel.
Turn on the main circuit breaker. See
page 36.
Reset the main circuit breaker once. See
page 36.
Turn on the main circuit breaker. See
page 36.
Wait five minutes. The charging circuit
breaker will automatically reset.
Disconnect the battery charger.
Exit freewheel mode and restart the
wheelchair.
Unlock the wheelchair.
Make sure that the backrest and the leg
rest are not tilted and that the seat is not
tilted or lifted.
Turn off the wheelchair and wait for the
motors to cool down.