Mitsubishi Electric MELSERVO MR-J4-B-LL Series Instruction Manual page 18

General-purpose ac servo
Table of Contents

Advertisement

1. FUNCTIONS AND CONFIGURATION
(c) 100 V class
Model MR-J4-_-LL
Rated voltage
Output
Rated current
Voltage/Frequency
Rated current
Permissible voltage
fluctuation
Main circuit
power supply
Permissible frequency
input
fluctuation
Power supply
capacity
Inrush current
Voltage/Frequency
Rated current
Permissible voltage
Control circuit
fluctuation
power supply
Permissible frequency
input
fluctuation
Power consumption [W]
Inrush current
Voltage
Interface power
supply
Current capacity
Control method
Dynamic brake
SSCNET III/H communication cycle
(Note 4)
Fully closed loop control
Scale measurement function
Load-side encoder interface
Communication function
Encoder output pulses
Analog monitor
Analog input
Digital I/O
Protective functions
Functional safety
Standards certified by CB
Response performance
(Note 3)
Test pulse input (STO)
Safety
Mean time to dangerous
performance
failure (MTTFd)
Diagnostic coverage (DC)
Average probability of
dangerous failures per
hour (PFH)
CE marking
Compliance to
global standards
UL standard
Structure (IP rating)
Close mounting (Note 2)
10B1
[A]
1.1
[A]
3.0
[kVA]
Refer to section 10.2 of "MR-J4-_B_(-RJ) Servo Amplifier Instruction Manual".
[A]
Refer to section 10.5 of "MR-J4-_B_(-RJ) Servo Amplifier Instruction Manual".
[A]
[A]
Refer to section 10.5 of "MR-J4-_B_(-RJ) Servo Amplifier Instruction Manual".
[A]
USB: connection to a personal computer or others (MR Configurator2-compatible)
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo motor
overheat protection, encoder error protection, regenerative error protection, undervoltage protection,
instantaneous power failure protection, overspeed protection, and error excessive protection
EN ISO 13849-1 category 3 PL d, IEC 61508 SIL 2, EN 62061 SIL CL2, EN 61800-5-2
20B1
3-phase 170 V AC
1.5
1-phase 100 V AC to 120 V AC, 50 Hz/60 Hz
5.0
1-phase 85 V AC to 132 V AC
Within ±5%
1-phase 100 V AC to 120 V AC, 50 Hz/60 Hz
0.4
1-phase 85 V AC to 132 V AC
Within ±5%
30
24 V DC ± 10%
(Note 1) 0.3 (including CN8 connector signals)
Sine-wave PWM control, current control method
Built-in
0.222 ms, 0.444 ms, 0.888 ms
Not available
Not available
Not available
Not available
Two channels
Three points (±10 V)
DI 1 point, DO 2 points
STO (IEC/EN 61800-5-2)
8 ms or less (STO input off → energy shut off)
Test pulse interval: 1 Hz to 25 Hz
Test pulse off time: Up to 1 ms
MTTFd ≥ 100 [years] (314a)
DC = Medium, 97.6 [%]
-9
PFH = 6.4 × 10
LVD: EN 61800-5-1
EMC: EN 61800-3
MD: EN ISO 13849-1, EN 61800-5-2, EN 62061
UL 508C
Natural cooling, open (IP20)
Possible
1 - 7
40B1
2.8
9.0
[1/h]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j4-dub-ll series

Table of Contents