The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of
purchasers of the 7800EMR-HYDRA2 product. Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the
operation of the 7800EMR-HYDRA2 product. Due to on going research and development, features and specifications in this manual are subject to
change without notice.
All rights reserved. No part of this publication may be reproduced without the express written permission of Evertz Microsystems Ltd. Copies of
this manual can be ordered from your Evertz dealer or from Evertz Microsystems.
7800EMR-HYDRA2
User Manual
Fax: 905-335-3573
Fax: 905-335-7571

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7800EMR-HYDRA2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for evertz 7800EMR-HYDRA2

  • Page 1 Version 1.0, April 2020 The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of purchasers of the 7800EMR-HYDRA2 product. Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the 7800EMR-HYDRA2 product.
  • Page 2 This page left intentionally blank...
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “Dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (Servicing) instructions in the literature accompanying the product.
  • Page 4 WARNING Changes or Modifications not expressly approved by Evertz Microsystems Ltd. could void the user’s authority to operate the equipment. Use of unshielded plugs or cables may cause radiation interference. Properly shielded interface cables...
  • Page 5 Evertz products are for informational use only and are not warranties of future performance, either expressed or implied. The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty, stated in the sales contract or order confirmation form.
  • Page 6 7800EMR-HYDRA2 User Manual This page left intentionally blank Page-ii Revision 1.0...
  • Page 7: Table Of Contents

    2.1.1. Rear Plate Suffix ......................3 2.1.2. Enclosures ......................... 3 2.1.3. Ordering Options ....................... 3 INSTALLATION ..........................5 3.1. INSTALLATION OF 7800EMR-HYDRA2 ON 7800FR FRAME ..........5 3.2. FRONT CARD EDGE CONTROLS AND LEDS ..............7 SERIAL CONFIGURATION ......................9 4.1. NETWORK CONFIGURATION ..................... 9 4.2.
  • Page 8 Figure 1-2 : 7800EMR-HYDRA2 Top View ...................... 2 Figure 3-1 : 7800EMR-HYDRA2 Rear Panel ....................5 Figure 3-2 : Illustration of 7800EMR-HYDRA2 card in 7800 Frame ..............6 Figure 3-3: 7800EMR-HYDRA2 Card Edge ..................... 7 Figure 4-1 : Network Configuration ........................9 Figure 4-2 : Audio Configuration ........................
  • Page 9: Overview

    User Manual OVERVIEW The 7800EMR-HYDRA2 interface module provides 7800EMR existing and new EMR audio systems the ability to integrate directly to Calrec Hydra2* audio systems, by means of a seamless bidirectional translation between Evertz TDM and Calrec Hydra2. Featuring primary and secondary Hydra2 paths...
  • Page 10: Figure 1-1 : 7800Emr-Hydra2 Block Diagram

    7800EMR-HYDRA2 User Manual Figure 1-1 : 7800EMR-HYDRA2 Block Diagram Figure 1-2 : 7800EMR-HYDRA2 Top View Page-2 Revision 1.0...
  • Page 11: Specification

    7800EMR-HYDRA2 User Manual SPECIFICATION 2.1. ORDERING INFORMATION 7800EMR–HYDRA2 TDM to Hydra2 bi–directional interface module ** Calrec Hydra2 Daughter Card to be purchased from Calrec 2.1.1. Rear Plate Suffix +3RU 3RU Rear Plate for use with 7700FR-C or 7800FR Multiframe 2.1.2. Enclosures...
  • Page 12 7800EMR-HYDRA2 User Manual This page left intentionally blank Page-4 Revision 1.0...
  • Page 13: Installation

    Before handling the card, it is important to minimize the potential effects of static electricity. It is therefore recommended that an ESD strap to be worn. 7800EMR-HYDRA2 module must have minimum 1 slot vacant in the frame. Each rear plate can house one 7800EMR-HYDRA2 module.
  • Page 14: Figure 3-2 : Illustration Of 7800Emr-Hydra2 Card In 7800 Frame

    7800EMR-HYDRA2 User Manual Step 2: Insert the 7800EMR-HYDRA2 card in the 7800 Frame and make sure the orientation of the card will be as is shown in Figure 3-2. Figure 3-2 : Illustration of 7800EMR-HYDRA2 card in 7800 Frame Page-6...
  • Page 15: Front Card Edge Controls And Leds

    3.2. FRONT CARD EDGE CONTROLS AND LEDS The 7800EMR-HYDRA2 front card edges have some key controls and indicators that can help in the installation and debugging processes. Figure 3-3 shows the card edges and Table 3-1 describe the expected behaviour of each component. When applied relevant signal to the card, the following card edge LED’s should light up.
  • Page 16 7800EMR-HYDRA2 User Manual This page left intentionally blank Page-8 Revision 1.0...
  • Page 17: Serial Configuration

    7800EMR-HYDRA2 User Manual SERIAL CONFIGURATION 4.1. NETWORK CONFIGURATION This section allows the user to configure the IP address, Netmask address, Gateway, Broad cast address and DHCP mode. Figure 4-1 : Network Configuration 4.2. AUDIO CONFIGURATION This section allows the user to configure and view Audio settings. To view the audio input packets and...
  • Page 18: Hid Address

    7800EMR-HYDRA2 User Manual 4.3. HID ADDRESS This section allows the user to check the HID address of H2M module. Go the menu (3) Audio Configuration, then (4) Hydra Module Options, then (10) Send HID request to Hydra module. HID address is used to communicate with the Calrec.
  • Page 19: Sfp Setup

    7800EMR-HYDRA2 User Manual 4.4. SFP SETUP This should detect the SFP and report back with a Vendor name (Avago, for instance). Go to option 6) Show SFP setup -> 1) Show SFP status, Figure 4-5 : SFP Status 4.5. PUSHING NAMES FROM MAGNUM ...
  • Page 20: Figure 4-6 : Carlec Setup

    (Use Secondary SFP location) 1. Calrec rack IP address is set to 192.1.1.0, to change this please refer to Calrec’s initial setup for Evertz document or the label on top of the chassis. Set your test pc’s 2 network adaptor IP address to 192.1.134.0 and Netmask 255.255.0.0 and MAC address to 000D07FF8600 (also called...
  • Page 21: Figure 4-7 : Calrec Webpage

    7800EMR-HYDRA2 User Manual Figure 4-7 : Calrec Webpage 4. Plug a third Copper SFP (SFPTR-RJ45-SER-AV) into the HYDRA2 PRI or secondary port (depending on testing port) on the rear plate and insert the CAT5 Hydra cable here. The Primary port is used as the Calrec ROUTER card is currently plugged into the primary half of the rack labelled as ROUTER1.
  • Page 22: Figure 4-9 : Patching

    7800EMR-HYDRA2 User Manual 5. Now refresh H2O from the browser and check that under the I/O Box & Setup tab there should be an entry for the H2M module 6. Go to the Manage Folders tab and under Port Folders click ‘+’ at the bottom and add a folder with a name ‘Hydra2_Mod-64-inputs’.
  • Page 23: Figure 4-10 : Magnum Interfaces

    7800EMR-HYDRA2 User Manual 1. Login Client Host with admin/admin and select “interfaces” tab and choose “Quartz” 2. Add Hydra2 with Port “4000” or available Port Figure 4-10 : MAGNUM Interfaces 3. Add Device under the Devices tab and Add Hydra2 sources and destinations.
  • Page 24 7800EMR-HYDRA2 User Manual This page left intentionally blank Page-16 Revision 1.0...
  • Page 25: Vistalink ® Pro Configuration

    7800EMR-HYDRA2 can communicate to VLPro using the control port of the card and appropriate Jar file. Open VistaLINK® PRO and click on the refresh tree icon.
  • Page 26 7800EMR-HYDRA2 User Manual This page left intentionally blank Page-18 Revision 1.0...
  • Page 27: Updating Vlpro Server Jar File

    UPDATING VLPRO SERVER JAR FILE Products from Evertz are constantly evolving and new features are often added. It is therefore important to update the JAR files in use to provide access to all the latest features or enhancements. It will also necessary to add JAR files for new products.
  • Page 28: Figure 6-2 : Vistalink Pro - Applying Jar Updates

    7800EMR-HYDRA2 User Manual Figure 6-2 : VistaLink PRO – Applying JAR Updates ® You will be prompted to restart the server to enable the change to take effect. Apply as many JAR updates as required before restarting the server. Figure 6-3 : VistaLink PRO –...
  • Page 29: Upgrading The Firmware On 7800Emr-Hydra2 Through Ftp

    7800EMR-HYDRA2 User Manual UPGRADING THE FIRMWARE ON 7800EMR-HYDRA2 THROUGH FTP 1. Identify and confirm the IP Addresses of the module and PC/laptop, and ensure that they are on same subnet. 2. Obtain the new firmware and copy to any directory on your computer. (C:\temp) 3.
  • Page 30: Figure 7-2 : Sample Ftp Upgrade Window

    7800EMR-HYDRA2 User Manual Figure 7-2 : Sample FTP Upgrade Window Page-22 Revision 1.0...