Table of Contents

Advertisement

Quick Links

© Copyright 2020
EVERTZ MICROSYSTEMS LTD.
5292 John Lucas Drive
Burlington, Ontario
Canada L7L 5Z9
Phone:
+1 905-335-3700
Sales:
sales@evertz.com
Tech Support: service@evertz.com
Web Page:
http://www.evertz.com
Version 1.0, June 2020
The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of
purchasers of the 570ACO-X19-10G series product. Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the
operation of the 570ACO-X19-10G series product. Due to on going research and development, features and specifications in this manual are subject
to change without notice.
All rights reserved. No part of this publication may be reproduced without the express written permission of Evertz Microsystems Ltd. Copies of this
manual can be ordered from your Evertz dealer or from Evertz Microsystems.
570ACO-X19-10G Series
Quick Reference Guide
Fax: +1 905-335-3573
Fax: +1 905-335-7571

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 570ACO-X19-10G Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for evertz 570ACO-X19-10G Series

  • Page 1 Version 1.0, June 2020 The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of purchasers of the 570ACO-X19-10G series product. Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the 570ACO-X19-10G series product.
  • Page 2 This page left intentionally blank...
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “Dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (Servicing) instructions in the literature accompanying the product.
  • Page 4 WARNING Changes or Modifications not expressly approved by Evertz Microsystems Ltd. could void the user’s authority to operate the equipment. Use of unshielded plugs or cables may cause radiation interference. Properly shielded interface cables with...
  • Page 5 Jun 2020 Information contained in this manual is believed to be accurate and reliable. However, Evertz assumes no responsibility for the use thereof nor for the rights of third parties, which may be affected in any way by the use thereof. Any representations in this document concerning performance of Evertz products are for informational use only and are not warranties of future performance, either expressed or implied.
  • Page 6 570ACO-X19-10G Series Quick Reference Guide This page left intentionally blank Page - ii Version 1.0...
  • Page 7: Table Of Contents

    570ACO-X19-10G Series Quick Reference Guide TABLE OF CONTENTS OVERVIEW ........................... 1 SPECIFICATIONS ......................... 3 2.1. SERIAL DIGITAL VIDEO ...................... 3 2.2. IP INPUT ..........................3 2.3. SERIAL VIDEO OUTPUT ..................... 3 2.4. IP OUTPUT ........................... 3 2.5. SWITCHING REFERENCE ....................3 2.6.
  • Page 8 570ACO-X19-10G Series Quick Reference Guide 4.3.2. Input Control ......................17 4.3.3. Failover Control ....................... 17 4.3.4. Output Control ......................18 4.4. ACS CRITERIA ........................18 4.4.1. Video Monitoring Control ..................19 4.4.2. Audio Monitoring Control ..................20 4.4.3. Audio Monitoring Per Group ..................21 4.4.4.
  • Page 9 570ACO-X19-10G Series Quick Reference Guide 4.17. SNMP TRAP ........................37 FIRMWARE UPGRADE ......................39 5.1. FIRMWARE UPGRADE USING WEBEASY ..............39 ® 5.2. FIRMWARE UPGRADE THROUGH VISTALINK PRO ............41 Figures Figure 1-1: 570ACO-X19-10G App A Block Diagram ..................2 Figure 1-2: 570ACO-X19-10G App B Block Diagram ..................
  • Page 10 570ACO-X19-10G Series Quick Reference Guide Figure 4-43: WebEASY - Audio Notify/Audio Stream Notify ................ 34 ® Figure 4-44: WebEASY - Audio Notify/Audio Channel Notify............... 35 ® Figure 4-45: WebEASY - ANC Notify ......................35 ® Figure 4-46: WebEASY - Notify/ Board Notify ....................36 ®...
  • Page 11: Overview

    570ACO-X19-10G Series Quick Reference Guide OVERVIEW The 570ACO-X19-10G is an auto clean switch designed for auto failover of SMPTE 2110 signals due to Video faults, Audio Faults or Data faults with selectable priority for each input signal. The 570ACO-X19- 10G contains 3 independent cores with 4x SMPTE 2110 inputs (A,B,C,D) with the capability of producing 2X SMPTE 2110 and HDSDI outputs from each core (Program &...
  • Page 12: Figure 1-1: 570Aco-X19-10G App A Block Diagram

    570ACO-X19-10G Series Quick Reference Guide Figure 1-1: 570ACO-X19-10G App A Block Diagram Figure 1-2: 570ACO-X19-10G App B Block Diagram Page - 2 Version 1.0...
  • Page 13: Specifications

    570ACO-X19-10G Series Quick Reference Guide SPECIFICATIONS 2.1. SERIAL DIGITAL VIDEO • SMPTE 424M (3Gb/s) • SMPTE 292M (1.5Gb/s) 2.2. IP INPUT Ethernet Interface: 8x 10GE SFP+(App A), 6x10GE SFP+(App B) Decapsulation: SMPTE2110 2.3. SERIAL VIDEO OUTPUT Standards: App A: STMPE 424M (3Gb/s), STMPE 292M (1.5Gb/s) App B: STMPE 292M (1.5Gb/s)
  • Page 14: Physical

    570ACO-X19-10G Series Quick Reference Guide 2.7. PHYSICAL Number of slots: 2.8. ENCLOSURES S570FR: 3RU chassis 570FR: 1RU chassis 2.9. ORDERING INFORMATION 570ACO-X19-10G Automatic change over with Audio / Video monitoring.10GE I/O and SDI outputs. (SFP+ sold separately) Page - 4...
  • Page 15: Getting Started

    570ACO-X19-10G Series Quick Reference Guide GETTING STARTED The 570ACO-X19-10G comes with a companion rear plate and occupies one slot in 570FR. Refer to Figure 3-1 for 570ACO-X19-10G front plate layout and Figure 3-2 for the 570ACO-X19-10G rear plate layout. 3.1.
  • Page 16: Back Plate

    570ACO-X19-10G Series Quick Reference Guide 3.2. BACK PLATE Figure 3-2: 570ACO-X19-10G Back Plate The back of the 570ACO-X19-10G has following connections: • 20 mini din connectors, only first 6 dins are used for ACO1, ACO2, ACO3 o Din 1 for...
  • Page 17: Care And Handling Of Optical Fiber

    The transmission characteristics of the fiber are dependent on the shape of the optical core and therefore care must be taken to prevent fiber damage due to heavy objects or abrupt fiber bending. Evertz recommends that the user maintains a minimum bending radius of 5 cm to avoid fiber bending loss that will decrease the maximum attainable distance of the fiber cable.
  • Page 18: 570Aco-X19-10G Input/Output Mapping

    570ACO-X19-10G Series Quick Reference Guide 3.5. 570ACO-X19-10G INPUT/OUTPUT MAPPING 3.5.1. App A Input/output mapping In total, 12 virtual SDIs (1A/1B/1C/1D, 2A/2B/2C/2D, 3A/3B/3C/3D) are converted from 2110 inputs. Each ACS does failover switching of input (A/B/C/D) and output 2 SDIs (PGM and PRV) and identical 2110 outputs.
  • Page 19: Web Interface

    570ACO-X19-10G Series Quick Reference Guide WEB INTERFACE Different product licenses will enable different product features. Depending on the product features enabled, there will be different tabs and controls that will need to be configured. For the purpose of this Quick Reference Guide, we have enabled all product features.
  • Page 20: Figure 4-2: Webeasy - Top Navigation Bar

    570ACO-X19-10G Series Quick Reference Guide Figure 4-2: WebEASY - Top Navigation Bar ® Top Navigation Bar • o Product Name: Displays the product Name o Refresh: Manually refreshes the user’s configuration o Auto Refresh: Automatically refreshes the user’s configuration o Apply: Manually saves the user’s configuration o Dynamic Apply: Automatically saves the user’s configuration...
  • Page 21: System Tab

    570ACO-X19-10G Series Quick Reference Guide 4.1. SYSTEM TAB 4.1.1. Control Port Configuration Figure 4-4: WebEASY - System/Control Port Configuration ® Eth0 The Eth0 tab shows the control IP address of the 570ACO. This IP address is only used when installed inside a S570FR standalone frame.
  • Page 22: Data Port Monitor

    570ACO-X19-10G Series Quick Reference Guide 4.1.3. Data Port Monitor Figure 4-6: WebEASY - System/Data Port Configuration ® For SFP 1-6 Ethernet Rx Bandwidth: This field shows the received Ethernet bandwidth. Ethernet Rx Frames OK: This field shows the number of Error-Free received frames.
  • Page 23: Sfp Monitor

    570ACO-X19-10G Series Quick Reference Guide 4.1.4. SFP Monitor Figure 4-7: WebEASY® - System\SFP Monitor For SFP 1-6 SFP Part Number: This parameter shows the part number of SFP installed. SFP Type: This parameter shows the type of SFP installed. SFP Rx Power level: This parameter shows the SFP’s received power level.
  • Page 24: Genlock Control

    570ACO-X19-10G Series Quick Reference Guide 4.1.6. Genlock Control Figure 4-9: WebEASY - System/Genlock Control ® Reference Selection: This dropdown menu allows the user to select the output reference. Options can include the following depending on what type of firmware is loaded: External Ref •...
  • Page 25: Time Management

    570ACO-X19-10G Series Quick Reference Guide 4.1.9. Time Management Figure 4-12 Management : WebEASY - System/Time ® Time Source: This control allows the user to select between two time sources, “Local” & “NTP”. Time zone Offset: This parameter allows the user to set different time zone.
  • Page 26: Product Features

    570ACO-X19-10G Series Quick Reference Guide 4.2. PRODUCT FEATURES 4.2.1. Product Features Figure 2-1: WebEASY -Product Features/Product Features ® For Product Features 1-20 Product Feature name: Product features which are supported on this card are listed here. All available product features are listed in different tabs.
  • Page 27: Acs Control

    570ACO-X19-10G Series Quick Reference Guide 4.3. ACS CONTROL 4.3.1. ACS Status Figure 4-16: WebEASY - ACS Status/ACS Control ® For Auto Clean Switch (ACS) 1-3 Current PGM Output Source: Show the current PGM output source i.e. input Stream A, B or C.
  • Page 28: Output Control

    570ACO-X19-10G Series Quick Reference Guide 4.3.4. Output Control Figure 4-19: WebEASY - ACS Status/Output Control ® Video Standard: This dropdown menu allows the user to select the video standard. PGM output Mode: This dropdown allows the user to set the PGM output mode i.e. IP input stream for PGM output either A,B,C or ACS.
  • Page 29: Video Monitoring Control

    570ACO-X19-10G Series Quick Reference Guide 4.4.1. Video Monitoring Control Figure 4-20: WebEASY - ACS Criteria/Video Monitoring Control ® For ACS 1-3 Video Missing Failover: Using this dropdown menu user can enbale/disable Failover when video is missing.If video missing Failover is disable then there won’t be any failover even video is missing.
  • Page 30: Audio Monitoring Control

    570ACO-X19-10G Series Quick Reference Guide 4.4.2. Audio Monitoring Control Figure 4-21: WebEASY - ACS Criteria/Audio Monitoring Control ® For ACS 1-3 Audio Missing Duration: This field allows to set Audio Missing Duration between 1 to 100000ms. Audio Missing Timeout: This field allows to set Audio Missing Timeout between 1 to 100000ms.
  • Page 31: Audio Monitoring Per Group

    570ACO-X19-10G Series Quick Reference Guide 4.4.3. Audio Monitoring Per Group Figure 4-22: WebEASY - ACS Criteria/Audio Monitoring Per Group ® For Audio Groups 1-4 Audio Missing Failover: This conrol allows the user to enable/disable Failover when audio group is missing.
  • Page 32: Anc Monitoring Control

    570ACO-X19-10G Series Quick Reference Guide 4.4.5. ANC Monitoring Control Figure 4-24: WebEASY - ACS Criteria/ANC Monitoring Control ® VANC Packet Missing Failover: This control allows to Enable/Disable failover when VANC Packets are missing. VANC Packet Missing Duration: This field allows to set VANC Packet Missing duartion betweeen 1 to 1000 frames.
  • Page 33: Sdi Control

    570ACO-X19-10G Series Quick Reference Guide 4.5. SDI CONTROL 4.5.1. SDI Output Control Figure 4-25: WebEASY - SDI Control/SDI Output Control ® For 1A to 3C • A1, B1, C1 are the input streams for ACO1/ACS1; • A2, B2, C2 are the input streams for ACO2/ACS2 •...
  • Page 34: Vpid Monitoring

    570ACO-X19-10G Series Quick Reference Guide 4.5.3. VPID Monitoring Figure 4-27: WebEASY - SDI Control/VPID Monitoring ® VPID Present: Shows that video Payload Id is preset or not. VPID Data: This field shows VIPD’s data. VPID Information: This field decribe the information for the Video Payload ID.
  • Page 35: Ip Output Advanced Control

    570ACO-X19-10G Series Quick Reference Guide 4.6.2. IP Output Advanced Control Figure 4-29: WebEASY - Video(S2110-20)IP Output/IP Output Advanced Control ® For PGM 1 to 3 and Prvw 1 to 3 (refer to 4.6.1 for details) IP Output Source IP Address: This field allows the user or control system to assign the source IP address for the corresponding SFP port.
  • Page 36: Video(S2110-20) Ip Input

    570ACO-X19-10G Series Quick Reference Guide 4.7. VIDEO(S2110-20) IP INPUT 4.7.1. Global Control Figure 4-31: WebEASY - Video(S2110-20)IP Input/Global Control ® Next Timeout: This field allows the user to set the next IP input timeout value. 4.7.2. IP Input Control Figure 4-32: WebEASY - Video(S2110-20)IP Input/IP Input Control ®...
  • Page 37: Ip Input Monitoring

    570ACO-X19-10G Series Quick Reference Guide 4.7.3. IP Input Monitoring Figure 4-33: WebEASY - Video(S2110-20)IP Input/IP Input Monitoring ® For 1A to 3C (refer to 4.5.1 for details) IP Output Present: This field indicates if IP Input is present or not. It will show up as Inactive or Active.
  • Page 38: Audio (S2110-30) Ip Output

    570ACO-X19-10G Series Quick Reference Guide 4.8. AUDIO (S2110-30) IP OUTPUT Figure 4-34: WebEASY - Audio(S2110-30)IP Output Tab ® For PGM 1 to 3 and Prvw 1 to 3 (refer to 4.6.1 for details) IP Output Status: This parameter shows the status of the IP output.
  • Page 39: Audio (S2110-30) Ip Input

    570ACO-X19-10G Series Quick Reference Guide 4.9. AUDIO (S2110-30) IP INPUT Figure 4-35: WebEASY - Audio(S2110-30)IP Input Tab ® For 1A to 3C (refer to 4.5.1 for details) IP Input Enable: This field displays the IP input status as Enabled or Disabled based on the routing set for the card.
  • Page 40: Anc (S2110-40) Ip Output

    570ACO-X19-10G Series Quick Reference Guide 4.10. ANC (S2110-40) IP OUTPUT Figure 4-36: WebEASY - ANC(S2110-40)IP Output Tab ® IP Output Status: This parameter shows the IP output status. Destination IP Address: This field allows the user or control system to assign the output IP address/multicast address.
  • Page 41: Ptp Control

    570ACO-X19-10G Series Quick Reference Guide 4.12. PTP CONTROL 4.12.1. PTP Control Figure 4-38: WebEASY - PTP Control/PTP Control ® For Main & Backup Ports SFP Port: This dropdown menu allows the user to select which SFP port to use for a main & a backup PTP source.
  • Page 42: Ptp Monitor

    570ACO-X19-10G Series Quick Reference Guide 4.12.2. PTP Monitor This section allows the user to monitor the current PTP status. Figure 4-39: WebEASY - PTP Control/PTP Monitor ® Active PTP: This field shows if PTP Main or PTP Backup is currently being used.
  • Page 43: Video Notify

    570ACO-X19-10G Series Quick Reference Guide 4.13. VIDEO NOTIFY In this tab. users can enable/disable video traps for Video Missing, Video Freeze, Video Packet Error and Video Black for all the streams for all ACO cores. Figure 4-40: WebEASY - Video Notify Tab ®...
  • Page 44: Audio Failover Notify

    570ACO-X19-10G Series Quick Reference Guide 4.14.2. Audio Failover Notify In this section, users can Enable/Disable Audio Traps for Audio Missing, Audio Silence and Audio Packet Error by selecting True/False from drop down menu. Figure 4-42: WebEASY - Audio Notify/Audio Failover Notify ®...
  • Page 45: Audio Channel Notify

    570ACO-X19-10G Series Quick Reference Guide 4.14.4. Audio Channel Notify Figure 4-44: WebEASY - Audio Notify/Audio Channel Notify ® For ACS 1 to 3 & Inputs A to 3 Audio Traps: When Enabled, a fault condition will send out a trap message to the trap addresses configured in the Trap Control section of the System tab.
  • Page 46: Notify

    570ACO-X19-10G Series Quick Reference Guide 4.16. NOTIFY 4.16.1. Board Notify In this section users can set the trap Board Fault and Refernce Loss Figure 4-46: WebEASY - Notify/ Board Notify ® Board Trap: This control allows to turn board traps ON or OFF.
  • Page 47: Clear Faults

    570ACO-X19-10G Series Quick Reference Guide 4.16.4. Clear Faults Figure 4-49: WebEASY - Notify/ ACS Notify/ Clear Faults ® Clear Faults: By clicking on Clear Faults button user can clear all the ACS Faults. 4.17. SNMP TRAP Figure 4-50: WebEASY - SNMP Trap/SNMP Trap ®...
  • Page 48 570ACO-X19-10G Series Quick Reference Guide This page left intentionally blank Page - 38 Version 1.0...
  • Page 49: Firmware Upgrade

    Should the firmware version be outdated, the user will need to download the firmware image file.  NOTE: Contact Evertz to get the latest firmware file. Figure 5-2: WebEASY® - Firmware Upgrade Menu Click Choose File and browse to locate image file.
  • Page 50: Figure 5-3: Webeasy® - Firmware Upgrade Menu

    570ACO-X19-10G Series Quick Reference Guide Figure 5-3: WebEASY® - Firmware Upgrade Menu Once selected, click Open (Step 1) to advance to next step. Click Upgrade (Step 2) and watch progress bar for status. Once completed, the device will automatically restart.
  • Page 51: Firmware Upgrade Through Vistalink Pro

    570ACO-X19-10G Series Quick Reference Guide 5.2. FIRMWARE UPGRADE THROUGH VISTALINK PRO To ensure that the 7708VB-4-1H-SE is running the latest firmware, follow the below steps: 1. Right click on the 570ACO under the Hardware menu Click on Version Information. 2. In version information window Select 570ACO-X19-10G under hardware.
  • Page 52: Figure 5-5: Vistalink Pro/Upgrade Firmware

    570ACO-X19-10G Series Quick Reference Guide Figure 5-5: VistaLINK Pro/Upgrade Firmware 8. Then after some time you will see Upgrade logon window with default username(customer) and password(customer). Click on Ok. Figure 5-6: VistaLINK Pro/Upgrade Logon 9. Once completed, the device will automatically reboot and you’ll see following window in VistaLINK...

Table of Contents