Wall Control Installation - Kaden KEX Series Installer Manual

Ducted gas heaters
Table of Contents

Advertisement

Kaden Installer's Manual
Ducted Gas Heaters

8. WALL CONTROL INSTALLATION

Kaden heating systems can be controlled by various Kaden Wall Controls. The Wall Control is located inside
the house and is wired directly to the heater. The wall control monitors the house temperature, and switches the
system ON and OFF to maintain a set temperature. So it MUST BE positioned correctly.
Install in the living area: It is important that the Wall Control is placed in a position that will provide the most
accurate reading of the temperature, i.e. in the area most often used for family living.
Attach on an internal wall: The temperature difference on an external wall can also affect it, so always mount it
on an internal wall. Keep the hole in the wall for the wiring as small as possible to prevent draughts from within
the wall cavity affecting the temperature setting.
Get the height right: The Wall Control should be approximately 1500mm above floor level.
Avoid hot spots: Keep the Wall Control as far away as possible from warm air outlets, radiation from the sun,
fireplaces, radio and television sets or warm pipes and duct running in the wall behind it.
Avoid cold spots: Keep it as far away as possible from draughts caused by doorways, stairwells, windows or
return air inlets.
Avoid dead spots: Keep it away from areas of less than normal air circulation e.g. behind doors, in alcoves or
corners.
Interference from other electrical connections: Ensure the Wall Control and wiring are kept away from other
electrical, data and antenna cables. This includes keeping the Wall Control's wiring away from the spark igniter
loom within the heater's cabinet.
Use the right cable: Use a cable of 0.75mm² in cross section and less than 100m in length.
DO NOT install the wiring with the power turned on, as the fuse may blow, which would not be
covered under warranty.
NOTE
ONLY use Kaden Wall Controls, as any failure relating to a non-Kaden Wall Control will not be
covered under warranty.
ONLY use alkaline batteries in a manual Wall Control. Other types can cause unwanted operation
of the heater when the batteries reach the end of their life.
The Kaden Networker controller is used as a Wired Wall Thermostat and is also the interface to
set Installer Parameters and obtain diagnostic information on the Kaden KUN4 and KUN5 Ducted
NOTE
Gas Heaters. A spare Networker should be kept on hand for such purposes.
28

Advertisement

Table of Contents
loading

Table of Contents