Outlet Register Chart - Kaden KEX Series Installer Manual

Ducted gas heaters
Table of Contents

Advertisement

7.1

OUTLET REGISTER CHART

System Model
KUN521
KUN5
KUN530
KUN415
KUN420
KUN4
KUN425
KUN430
KUN315
KUN320
KUN3
KUN325
KUN330
KEX415 (300mm)**
KEX420 (300mm)**
KEX4
KEX420XA (350mm)**
KEX428 (350mm)**
KEX428XA (400mm)**
KEX315 (300mm)**
KEX320 (300mm)**
KEX3
KEX320XA (350mm)**
KEX328 (350mm)**
KEX328XA (400mm)**
** Model and base box duct size.
Airflow figures are based on a total static pressure of 125 Pa for 30 & 35 models and 50 Pa for
other models.
NOTE
Kaden Network 516 modules can only be used on KUN4 and KUN5 model heaters for adaptive
zoning.
A
Airflow
Recommended
Rate (L/s)
Maximum Ceiling
785
12
1000
17
620
10
620
10
630
10
895
16
475
10
540
10
650
11
895
13
498
N/A
581
N/A
622
N/A
896
N/A
1012
N/A
498
N/A
581
N/A
622
N/A
896
N/A
1012
N/A
Table 6
B
Min' Floor / Ceiling
Min' Floor / Ceiling
(Adaptive Zoning Only)
5
7
6
6
6
7
5
5
6
8
4
5
5
8
8
4
5
5
8
8
C
1.5
2
2
2
2
2
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
27

Advertisement

Table of Contents
loading

Table of Contents