Offgridtec IC-24/3000/100/80 User Manual page 40

Inverter/charger
Table of Contents

Advertisement

Dry contact
20
OFF voltage
Maximum
21
charging
current
Max. utility
22
charging
current
24
Clear fault
Clear the
PV
25
accumulate
d energy
Battery
26
capacity
Temperatur
27
e
compensat
AGM(Default)/GEL/FLD: 24.0V
LFP8: 24.0V
LCNM7: 24.5V
AGM(Default)/GEL/FLD: 48.0V
LFP15: 45.0V
LFP16: 48.0V
LCNM14: 49.0V
User define for the 24V system: 21.6~32.0V
Step size: long press for 1V,short press for 0.1V
User define for the 48V system: 43.2~64.0V
Step size: long press for 1V,short press for 0.1V
IC-24/3000/100/80: 100A (Default)
User define: 5~100A
IC-48/5000/80/60: 80A (Default)
User define: 5~80A
Step size: long press for 50A,short press for 5A
IC-24/3000/100/80: 80A (Default)
User define: 2~80A
IC-48/5000/80/60: 60A (Default)
User define: 2~60A
Step size: long press for 10A, short press for 1A
OFF (Default)
ON
OFF (Default)
ON
100AH (Default)
User define:1~4000AH
Step size:
Below 200AH: long press for 10A, short press for 1A
Above 200AH: long press for 50A, short press for 5A
CAUTION: To accurately display the battery capacity,
the customer needs to set this item according to the
actual battery capacity.
3 (Default)
0 (lithium battery)
0~9 (non-lithium battery)
38