Offgridtec IC-24/3000/100/80 User Manual page 39

Inverter/charger
Table of Contents

Advertisement

Auxiliary
17
module
OFF voltage
Auxiliary
18
module ON
voltage
Dry contact
19
ON voltage
AGM(Default)/GEL/FLD: 64.0V
LFP15: 54.5V
LFP16: 58.0V
LCNM14: 60.0V
AGM(Default)/GEL/FLD: 28.0V
LFP8: 26.6V
LCNM7: 27.0V
AGM(Default)/GEL/FLD: 56.0V
LFP15: 50.0V
LFP16: 53.3V
LCNM14: 54.0V
AGM(Default)/GEL/FLD: 24.0V
LFP8: 24.0V
LCNM7: 24.5V
AGM(Default)/GEL/FLD: 48.0V
LFP15: 45.0V
LFP16: 48.0V
LCNM14: 49.0V
AGM(Default)/GEL/FLD: 22.2V
LFP8: 22.2V
LCNM7: 21.7V
AGM(Default)/GEL/FLD: 44.4V
LFP15: 41.6V
LFP16: 44.4V
LCNM14: 43.4V
User define for the 48V system: 43.2~64.0V
Step size: long press for 1V,short press for 0.1V
User define for the 24V system: 21.6~32.0V
Step size: long press for 1V,short press for 0.1V
NOTE: The difference between AOF and AON should
be larger than or equal to 0.5V, or else the setting
cannot be saved.
User define for the 48V system: 43.2~64.0V
Step size: long press for 1V,short press for 0.1V
NOTE: The difference between AOF and AON should
be larger than or equal to 1V, or else the setting
cannot be saved.
User define for the 24V system: 21.6~32.0V
Step size: long press for 1V,short press for 0.1V
NOTE: The difference between AOF and AON should
be larger than or equal to 0.5V, or else the setting
cannot be saved.
User define for the 48V system: 43.2~64.0V
Step size: long press for 1V, short press for 0.1V
NOTE: The difference between AOF and AON should
be larger than or equal to 1V, or else the setting
cannot be saved.
User define for the 24V system: 21.6~32.0V
Step size: long press for 1V,short press for 0.1V
User define for the 48V system: 43.2~64.0V
Step size: long press for 1V,short press for 0.1V