3)
Connect the battery
A circuit breaker must be installed on the battery side. For selection, please refer to chapter
"2.2.2 Prepare modules
WARNING
 When wiring the battery, please do not close the circuit breaker and ensure that the
leads of "+" and "-" poles are connected correctly.
 A circuit breaker current is 1.25 to 2 times the rated current must be installed on the
CAUTION
battery side away from the battery not longer than 200mm.
Connection sequence of the battery
Step1: Remove the screw of the inverter/charger positive terminal with a sleeve, the torque of which is 3.5N.M.
Step2: Connect the ring terminal of the battery connection wire to the inverter/charger's positive terminal.
Step3: Install the screw and secure it with the sleeve.
Step4: Connect and secure the negative terminal of the inverter/charger following the step1~step3.
4)
Connect the AC load
 Risk of electric shock! When wiring the AC load, please do not close the circuit breaker
and ensure that the poles leads are connected correctly.
 If utility input exists, the inverter/charger must be connected to the ground terminal.
WARNING
 We do not assume any responsibility for the unnecessary danger when the ground
terminal is not connected correctly.
Silk-screen
L
N
".
Abbreviation
LINE
Neutral
16
Name
Live wire
Neutral line
Ground line
Color
Brown/black
Blue
Yellowish-green