Included accessories 1pcs (Details refer to the "Accessories list" file shipped with the inverter/charger.)
2.2.2 Prepare modules
1)
Battery
Recommended wire size of the battery and the circuit breaker is as below.
Model
UP3000-HM10022
UP5000-HM8042
Making the battery connection wire
Step1: Ring terminal 2pcs (included accessories).
Step2: Battery positive and negative connection wires 2 pcs(red +, black -). The wire length is determined
according to the customer's actual requirement.
Step3: Strip one end of the battery connection wire for about d mm (size d is determined according to the ring
terminal).
Step4: Pass the exposed wire through the ring terminal, and secure the wire firmly with a wire clamp.
2)
AC Load
Recommended wire size of the AC load and the circuit breaker is as below.
Model
IC-24/3000/100/80
IC-48/5000/80/60
Making the connection wire of the AC load:
Strip the AC load connection wires (3 pcs) for about 10 mm.
Symbols
L
N
3)
PV modules
Recommended wire size of the PV module and the circuit breaker is as below.
Battery wire size
35mm
/1AWG
2
35mm
/1AWG
2
Load wire size
4mm
/11AWG
2
6mm
/9AWG
2
Abbreviation
LINE
Neutral
11
Circuit breaker
2P—200A
2P—200A
Circuit breaker
2P—25A
2P—40A
Name
Live wire
Neutral line
Ground line
Ring terminal
RNB38-8S
RNB38-8S
Torque
1.2N.M
1.2N.M
Color
Brown/black
Blue
Yellowish green