Technical Data For Ul1480 / Ulc-S541, Ul1480A / Csa C22.2 No.205 Installations - Electro-Voice EVID S Series Installation Manual

Surface mount
Hide thumbs Also See for EVID S Series:
Table of Contents

Advertisement

Available languages

Available languages

en | Technical data for UL1480 / ULC-S541, UL1480A / CSA C22.2 NO.205
18
installations
6
Technical data for UL1480 / ULC-S541, UL1480A / CSA
C22.2 NO.205 installations
UL1480A/CSA C22.2 NO. 205 rated frequency
1
Average 400 Hz to 4 kHz
UL1480 and ULC-S541 Sound level data
Voltage (Vrms)
70
100
15,5
2022-03 | 07 | F.01U.345.358
UL1480/ULC-S541 rated frequency range: 400 Hz - 4 kHz
Sensitivity (SPL 1 W / 1 m)
Power handling (@ 8 Ω): 30 W
Input configuration: 8 Ω; 70 V / 100 V
70 V / 100 V power taps: 8 / 15 / 30 W (70 V) 16 / 30 W (100 V)
Cabinet construction: UL94-5VB rated enclosure and baffle
Grille construction: Power-coated Aluminum
Included accessories: Terminal weather cover
Power Tap (W)
8
15
30
16
30
8Ω (30W)
55 Hz - 20 kHz
range:
1
: 87 dB
Rated impedance: 8 Ω
60 W transformer tap not to be used in
UL1480 / ULC-S541, UL1480A / CSA C22.2
NO. 205 installations
Mounting system: U-Bracket
Acoustic design: Two-way design, internally damped, with
passive crossover
Approvals: UL1480 / ULC-S541, UL1480A / CSA C22.2
NO. 205; CE
OSPL (dBA)
UL Reverberant
87,8
90,2
92,5
90,5
92,8
91
Installation Manual
EVID Surface Mount S Series - X Models
ULC Anechoic
88,9
91,3
93,9
91,8
94,1
93,1
Electro-Voice