Panasonic SA-VK72DGCS Service Manual page 27

Dvd stereo system

Advertisement

Item
Measurement of
CD laser
current
electricity
User
initialization
Region display
PDF created with pdfFactory Pro trial version
Operational
Condition and
Key Function
While the player
Measurement of CD laser
is stopped and no
current electricity /
disc is inserted,
Measures CD laser current
press and hold
electricity and displays the
result together with the
down the
initialization value stored in
button on the
EEPROM. After
player and the
measurement, CD laser is lit
number button
till the power is turned off
"3" on the remote
(or goes off when the
controller unit.
primary power is turned off).
Press "FL
Display" button
for next page
While the player
User initialization / The user
is stopped and no
setting recovers the factory
disc is inserted,
setting.
press and hold
down the
button on the
player and the
number button
on the
remote controller
unit.
While the player
Region display
is stopped and no
disc is inserted,
press and hold
down the
button on the
player and the
number button,
"6" on the remote
controller unit.
www.pdffactory.com
Details
LDC
(display1/display2) / /
CD laser current
electricity measurement
mode /
electricity initialization
value stored in EEPROM /
: Present value of
*3
current electricity
Values are shown in the
decimal digit. The above
example indicates the
current electricity
initialization value is
28mA and its present
value is 26mA when laser
is turned on.
"INIT"
[s rr zzz] / / s : Panecon
model type / rr : Panecon
release number
zzz: Syscon release
number
27
Display
/xxx
yyyy
*1
*2
*3
Automatically
:
*1
exits
mode
five
: Current
*2
Automatically
exits
mode
five
Automatically
exits
mode
five
TO

Advertisement

loading

This manual is also suitable for: