(*) If "D" type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months.
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE "A" - PARAMETERS
Any modification of parameters/logics must be confirmed by pressing S2 > 5s
TRIMMER
Parameter
Automatic
T1
closing time [s]
T2
Work time [s]
Motor 1 closing
T3
delay time [s]
10 -
ALCOR AC A
INSTALLATION MANUAL
Definition
LINE
NEUTRAL
START + CONDENSER
COM
START + CONDENSER
START + CONDENSER
COM
START + CONDENSER
AUX 0 – POWERED CONTACT
230V (N.O.) (40W MAX)
0V-
24V+
24 Vsafe+
Common
START
OPEN
Common
STOP
PHOT (*)
FAULT 1
BAR /
BAR CL /
BAR TEST /
BAR CL TEST /
BAR 8K2 /
BAR CL 8K2
(*)
FAULT 2
ANTENNA
SHIELD
+
+
+
min.
max.
default
Waiting time before automatic closing.
0
120
0
NOTE: Set to 0 if not used.
Adjusts the motors' work time, lapsing which they will stop.
5
90
50%
Motor 1 closing delay time with respect to motor 2.
0
25
25%
NOTE: set 0 for single motor operations (leaf 1).
Single-phase power supply
Motor and condenser connection
Connection between motor and capacitor 2.
Note: if T3=0 do not connect any cable to clamps 14-15-16
Exit due to FLASHING LIGHT
Contact stays closed while leaves are operating.
Accessories power supply output.
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output act ive only during operating cycle.
START and OPEN inputs common
START command button (N.O.).
Operation according to "Residential / apartment building operation" logic
OPEN command button (N.O.).
Gate opened with this command. If the input stays closed, the leaves stay open until the
contact is opened.
When the contact is open, the automated device closes following the TCA time, where
activated.
STOP, PHOT and BAR inputs common
The command stops movement. (N.C.)
If not used, leave jumper inserted.
PHOTOCELL input (N.C.).
Operation according to "PHOTOCELL/PHOTOCELL DURING CLOSING" logic. If not used, leave
jumper inserted.
Test input for safety devices connected to PHOT.
Safety edge input (N.C.).
If not used, leave jumper inserted
BAR/8K2
Safety edge
Safety edge
check
operation
dip
dip
dip
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
Test input for safety devices connected to BAR / BAR CL
Antenna input.
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver.
Metal bodies close to the antenna can interfere with radio reception. If the transmitter's
range is limited, move the antenna to a more suitable position.
Description
NC input, no verification, reversal while
opening and closing (BAR)
NC input, no verification, reversal only
when closing, stop when opening (BAR
CL)
NC input, with verification, reversal
while opening and closing (BAR TEST)
NC input, with verification, reversal only
when closing, stop when opening (BAR
CL TEST)
8K2 input, reversal when opening and
closing (BAR 8K2)
8K2 input, reversal only when closing,
stop when opening (BAR CL 8K2)
Description