WALDIS PRIMOR 1000 Operating Instructions Manual

Advertisement

Quick Links

www.tresore.ch
OPERATING INSTRUCTIONS
SAFE LOCK
PRIMOR 1000 / 3000
Electronic safe lock for WA safes

Advertisement

Table of Contents
loading

Summary of Contents for WALDIS PRIMOR 1000

  • Page 1 OPERATING INSTRUCTIONS SAFE LOCK PRIMOR 1000 / 3000 Electronic safe lock for WA safes...
  • Page 2 Many thanks! ❤️ Many thanks for choosing Waldis to give you the security you want. The safe you have decided to purchase is a product tested in compliance with the EN1143-1 standard. A Swiss quality product with security tested by the VdS (German Association of Indemnity Insurers).
  • Page 3: Table Of Contents

    Table of contents Overview ..........................1 1.1. Operating controls: WALDIS Basic 480 ..............1 1.2. Operating controls: WALDIS Eco and Business ............. 1 Starting to use your safe ....................2 Operation ..........................3 3.1. Opening the safe ......................3 3.2.
  • Page 4: Overview

    Overview The PRIMOR 1000 / 3000 is installed as a standard lock in the WALDIS Basic 480 safe model and the WALDIS Eco / Business series of models. 1.1. Operating controls: WALDIS Basic 480 Input unit Rotary opening handle 1.2.
  • Page 5: Starting To Use Your Safe

    Starting to use your safe As soon as the safe has been delivered and correctly anchored, you can start operating the lock and using the safe. To do so, please keep to the following procedure: 1. Check that the rotary opening handle is in the "closed"...
  • Page 6: Operation

    Operation 3.1. Opening the safe To open the safe, please keep to the following procedure: 1. First, press the rotary opening handle counterclockwise into the "closed" position to make sure that the lock bolt is relieved of pressure. 2. Enter the code and within 3 seconds after the double acoustic signal, turn the rotary opening handle clockwise into the "open"...
  • Page 7: Reprogramming Codes

    3.3. Reprogramming codes NOTE: A new code must always be programmed with the door open, and it must be tested! If the code has been forgotten or can no longer be reconstructed, an emergency opening of the safe must be performed and it must be repaired or replaced at the owner's expense! The certification lapses in case of a repair.
  • Page 8: Replacing The Battery

    3.4. Replacing the battery If it is necessary to replace the battery (section 4.1.), keep to the following procedure: 1. Purchase a battery (9V ALKALINE Note the expiration date! block battery) 2. Using the lug positioned on top of the keypad, release the keypad by pulling it out of the input unit.
  • Page 9: Malfunctions

    Malfunctions 4.1. Battery If there is insufficient battery voltage, a warning signal will sound several times in succession after you enter the code, and the red LED will flash on and off intermittently. If you observe the warnings just mentioned, the 9 V block battery for the lock must be replaced as quickly as possible (section 3.4.).

This manual is also suitable for:

Primor 3000

Table of Contents