  • Page 1 Instruction Manual Waterproof Digital Thermometers Model SK-250WPⅡ-T Model SK-250WPⅡ-R...
  • Page 2: Notes On Use

    Thank you for purchasing the SK-250WPⅡseries Waterproof Digital Thermometer. - This product is designed to measure temperature. Do not use it for other purposes. - Read this manual carefully before using the thermometer. Keep the manual in a safe place for future reference whenever necessary.
  • Page 3 3. Features - Both the main unit and the probes have a waterproof structure that conforms to “Protection level 6 in JIS C 0920” that is equivalent to IP X6 They will not be affected in function at the touch of wet hands or with splashes of water.
  • Page 4 4. Names of Section 4-1 Main housing ■ Front view ■ Rear view SK-250WPⅡ-T SK-250WPⅡ-R (1) POWER ON/OFF key - Press this key to turn the main unit on. Press the key again to turn it off. (2) HOLD key (▼) - Press the HOLD key to hold (freeze) temperature readings.
  • Page 5 (9) DATA key (SK-250WPⅡ-R) - Press the DATA key to recall data recorded on the unit to the display. Key Operations in Setting and Timer modes Operation HOLD (▼) Decreases the value. MAX/MIN (▲) Increases the value. RESET Resets the set value to the default value. MODE (only in setting mode) Moves to the next setting item.
  • Page 6: How To Use

    5. How to Use 5-1. Loading Batteries (1) Rotate the screw on the battery lid on the back of the main unit counterclockwise using a blade screwdriver or a coin until it comes free and then remove the lid. (2) Load two AAA batteries so that each positive or negative terminal faces the correct direction as shown in the battery compartment.
  • Page 7 6. How to measure temperature (1) Connect the probe to the main unit NB. If the probe is disconnected when power is turned on, error message “Er” will be displayed. By connecting the probe, display changes to measurement mode. (2) Press the POWER ON/OFF key to turn the power on. The current temperature will display and it will be in measurement mode.
  • Page 8 11. Timer Note: The timer function cannot be used while the hold, MAX/MIN or record function is being used. No other functions except the upper/lower temperature alarm function can be used while the timer is being used. (1) Press the START/STOP key while in the measurement mode. The display of "TIMER" lights up to indicate that the timer function is turned on (default timer state).
  • Page 9: Setting Mode

    (3) When the counting down ends, the clock display starts blinking and the buzzer starts sounding (30 seconds). To stop the blinking and sounding, press any key. The unit returns to the setting mode for count down when the buzzer sounding ends or is stopped. * If the upper/lower temperature alarm is triggered, the timer's tweeting sound stops and switches to the alarm sound (the blinking clock display remains).
  • Page 10 (3) Press the SET key to confirm the hour setting. The minute digits start blinking to indicate that the unit has entered the minute setting mode. (4) Press either the MAX/MIN key (▲) or HOLD key (▼) to set the minute digits. To cancel the minute setting, press the RESET key.
  • Page 11 14-2. Lower Temperature Alarm (1) Press the MODE key three times while in the measurement mode. The display of "Alarm Lo" starts blinking. (2) Press the START/STOP key to turn the function on ("on") or to cancel ("oFF"). Setting is not possible while "oFF"...
  • Page 12: Auto Power Off Function

    100.0°C. If the upper alarm is changed to "on" with 100°C, the lower alarm becomes "oFF" with -50°C (the default). (4) If the value for the upper alarm becomes smaller than that for the lower alarm when the lower alarm is changed from "oFF"...
  • Page 13: Default Setting

    16-2. Calling Up Data (1) Press the DATA key while in the measurement mode to call up data onto the display. The recorded data item appears in order from No. 1 each time the DATA key is pressed. Pressing and holding the DATA key displays recorded data continuously.
  • Page 14: Specifications

    20-1. Specifications Model : No. 8064-00 Waterproof Digital Thermometer SK-250WPⅡ-T Display range : -55 to 305°C (Measuring range is different depending on the probes connected) Display Accuracy : ± (0.1°C + 1 digit) at 9.9 to 199.9°C : ± (1°C + 1 digit) at other than above. Resolution : 0.1°C at -9.9 to 199.9°C : 1°C at other than above...