- Industrial Wireless IoT solution Quick Start Guide 4. SETUP Instructions 4.1. Bullseye Board Setup • Verify Jumper on is present on P8 (to power the Inductive position sensor circuitry) (Fig.1) • Break-off the small Actuator PCB attached to the lower left corner of the Bullseye board, by twisting up/down with your hand or using cutters.
Page 4
- Industrial Wireless IoT solution Quick Start Guide 4.2. Power the Bullseye Board • For demonstration purposes, connect a +5V USB power supply, or a computer USB port, to the USB micro-B connector (J1) “USB Power+Data” at the top left of the Bullseye board (Fig.5). •...
Page 5
- Industrial Wireless IoT solution Quick Start Guide 5. Out-Of-The-Box (OOB) Demo 5.1. Power-up See Setup instruction in Section 4.2 5.2. WIFI Pairing 5.2.1. Bullseye Board: ▪ Press Button (S3) once to initiate pairing mode => Blue LED flashing 2 times/sec 5.2.2.
Page 6
- Industrial Wireless IoT solution Quick Start Guide After several seconds (30 – 60 seconds typically), a confirmation of successful pairing message with IP address should be shown on the screen. The PAN9520 on Bullseye is now paired with the selected WIFI Network.
Page 7
- Industrial Wireless IoT solution Quick Start Guide 6. Bullseye (PAN9520) Embedded Web Page Bullseye’s OOB demo application aims at demonstrating the PAN9520 features and advantages for IoT solutions. Through its embedded web page interface, the demo application provides antenna test, inductive position sensing demo, battery / charging voltage monitoring and remote control functions.
Page 8
- Industrial Wireless IoT solution Quick Start Guide 6.3. Position Sensor Displays live graph of the Inductive Position Sensor. The graphic bar will move to indicate the center position of the break out actuator board as it moving along the 2 inch long sensing track. The bar graph scale is 2 inches.
- Industrial Wireless IoT solution Quick Start Guide 7. Appendix 1 - Inductive Position Sensor Calibration The Bullseye board features the Renesas ZMID4200 inductive position sensor, which is configured to provide a proportional voltage output relative to the actuator position (between 0 to 2 inches), and the output voltage range is set at 5% to 50% of the ZMID4200 supply voltage (~5V) to comply with the ADC input requiremments (~2.5Vmax).
- Industrial Wireless IoT solution Quick Start Guide 8. Appendix 2 – Bullseye Firmware Programming All Bullseye boards has been pre-programmed at the factory. However new firmware update may be needed from time to time. Please verify your Bullseye board firmware version by checking the bottom right of the PAN9520's embedded web page interface once connected.
Page 11
- Industrial Wireless IoT solution Quick Start Guide • In the first row, click the three dots to select the binary file, and the offset “0x0”, then click the check mark on the left to select this file to be programmed. •...