UV-SPH UV-SPH-HP UV-SPH-P Series UV-SPH-P-HP Series Series Series UV-SPH-U Series UV-SPH-U-HP Series APPLIED MEMBRANES - NSF/ANSI Standard 55 Class A NSF/ANSI Standard 55 Class B Standard Systems System Tested and Certified by System Tested and Certified by Rated Rated NSF International, NSF/ANSI 55...
Page 2
This is chemical free process which is simple in its concept and effective in its abilities to inactivate microorganisms present in the water supply. Simple maintenance, continuous disinfection and ultimately safe water, Applied Membranes makes it that easy.
TABLE OF CONTENTS Safety Considerations ......................4 Before You Begin ........................ 4 Water Quality Parameters ....................5 Assembly ..........................6 System Sizing ........................8 Location ..........................8 Installation ......................... 9 System Disinfection ......................12 Cleaning the Quartz Sleeve ....................12 Cleaning the UV Sensor ....................
Safety Considerations Although your UV system has been manufactured to the highest safety standards, care must be followed when operating and/or maintaining your system. 1. Before servicing this equipment, disconnect the power cord from the electrical outlet. 2. Energy given off by the UV lamp is harmful to your eyes and skin. NEVER look directly at an illuminated UV lamp without adequate eye protection and always protect your skin from direct exposure to the UV light.
80% for pre-treatment recommendations) You can have your water tested at a private analytical laboratory or by your local dealer. It is always recommended to install pre-filtration of at least 5 microns prior to a Applied Membranes UV disinfection system.
Assembly Unpack the system and ensure all the components are included with the system. Your system is shipped with the following components: Standard output lamp systems LAMP KEY GLAND NUT CONTROLLER UV-320006 UV-CH-US UV-CHP-US O-RING UV-300038 UV LAMP UV-SPH-2-L UV-SPH-3-L UV-SPH-6-L UV-SPH-11-L UV-SPH-21-L...
System Sizing All Applied Membranes UV systems are rated for a specific flow rate in water that meets the quality parameters on page 5. PLEASE NOTE that increasing the flow above this rating or disin- fecting water that does not meet the quality parameters will decrease the dose and therefore compromise the microorganism inactivation.
UV lamp and/or quartz sleeve (See Figure 2). The controller will require a ground fault circuit interrupter (GFCI or GFI) outlet and should be mounted beside or above the reactor. PLEASE NOTE: All Applied Membranes UV disinfection systems are intended for indoor use only as they should not be exposed to the elements.
Page 10
Step 6: Once the system has been plumbed in, gently remove the quartz sleeve from its packaging being careful not to touch the length with your hands. The use of cotton gloves is recommended for this procedure as oils from the hands can leave residue on the sleeve and lamp which can ultimately block the UV light from getting to the wa- ter.
Page 11
Step 11: Always hold UV lamps by their ceramic ends, not by the lamp quartz. Remove the lamp from its packaging. Again, the use of cotton gloves is recommended. Remove the lamp key from the lamp’s connector and set it aside for the next step. Be careful to not touch the key’s exposed contacts.
Reinstall the filter cartridge into the sump and flush the chlorine solution by opening all faucets until chlorine can no longer be detected. Your home has now been completely disinfected with your Applied Membranes UV system ready to inactivate any microorganisms that enter the home.
Replace sensor following step 9 from the installation section of the manual. Operation Applied Membranes systems come with a feature laden controller that incorporates both the lamp driver (ballast) and control features in one water-tight case. Four main controllers are available for the Applied Membranes systems (depending on your model).
When the UV lamp is not on or the lamp life has expired, the LED will be illuminated red and an audible buzzer will be sounding. To remedy this condition, the UV lamp must be replaced with a new genuine Applied Membranes UV lamp. UV-SPH-HP UV-SPH...
A final module screen is displayed showing which specific modules were initialized. The controller then displays the lamp optimization screen for 60 seconds to allow the lamp to reach its optimum output. Finally, a final “start-up complete” screen is displayed. The system will now be ready to disinfect water flow.
audible chirp every audible chirp every constant audible cycles with red low 15 seconds 15 seconds alarm UV screen Lamp Countdown Sequence The system counts down the number of days until a lamp change is required. UV-SPH-P UV-SPH-U UV-SPH At thirty days remaining, the LED or display screen will change to a yellow caution indicator. At seven days remaining, the system will additionally repeat an audible chirp.
Users with a camera phone equipped with the correct reader application can scan the image of the QR code and over a wireless network connect to a Applied Membranes web page in the phone’s browser. Applied Membranes’ QR webpage has information on how to purchase replacement components as well as a helpful video directory on system servicing (i.e.
System Troubleshooting Hard Alarms: The following give a constant audible alarm. If present, the solenoid valve is closed, and the 4-20, remote alarm and WiFi modules transmit the alarm. System Display Problem Resolution Reset lamp protection circuit -unplug unit for 10 seconds. The system has detected Replace the lamp with the a problem with the...
Page 19
Soft Alarms: The following remaining errors give a 15 second audible chirp only System Display Problem Resolution Ensure all modules are connected properly to the system and to each other. The module indicated Modules can be tested indi- is no longer vidually by plugging in one communicating to at a time and cycling power...
In extreme situations, elevated water temperature or fluctuation in temperature can lower the output of the UV lamp. In these cases, or if the elevated water temperature is a nuisance, Applied Membranes recommends one of the following forms of temperature management devices.
Optional Equipment Modules UV-SPH-P & UV-SPH-U controllers incorporate an “Infinite Expandability Port” (IEP) which allows for expansion to the UV sensor and all other modules. Each module comes with both a male and female connection. Connect any device to the controller and all subsequent devices are then connected into the female end of last device added in a “daisy chain”...
Performance Data Sheet (on all NSF/ANSI Standard 55, Class A Systems) System Tested and Certified by NSF International, NSF/ANSI 55 for Disinfection Performance, Class A SPNSFA- SPNSFA- 1.6M 2.2M Model SPNSFA- SPNSFA- SPNSFA- SPNSFA- SPNSFA- SPNSFA- SPNSFA- SPNSFA- 3.4M 6.3M 7.9M 2.2M-HP 4.0M-HP...
Performance Data Sheet (on all NSF/ANSI Standard 55, Class B Systems) System Tested and Certified by NSF International, NSF/ANSI 55 for Disinfection Performance, Class B SPNSFB- SPNSFB- SPNSFB- SPNSFB- SPNSFB- Model SPNSFB- SPNSFB- SPNSFB- SPNSFB- SPNSFB- 5.4-HP/ 7.6-HP/ 13-HP/ 22-HP/ 28-HP/ 2.9/M 5.2/M...
Applied Membranes will not be liable for damage or wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair, or if the product was not installed in accordance with the Manufacturers printed installation and operating instructions.
Your Dealer / Distributor will obtain a Warranty Return Authorization and will then need to return the product to Applied Membranes, together with proof of purchase and installation date, failure date, and supporting installation data. Any defective product to be returned must be sent freight prepaid.