Applied Membranes AAA-124 Installation And Service Manual

Applied Membranes AAA-124 Installation And Service Manual

Under-the counter 4 stage reverse osmosis system

Advertisement

Quick Links

Installation and Service Manual
Under-The Counter 4 Stage
Reverse Osmosis System
System Flow Rate
12 Gallons Per Day
24 Gallons Per Day
36 Gallons Per Day
Industry Leader in RO Expertise and Membrane Applications Since 1983™
2325 Cousteau Ct., Vista, CA 92081, USA • www.appliedmembranes.com
Model Number
AAA-124
AAA-244
AAA-364
System Flow Rate
50 Gallons Per Day
75 Gallons Per Day
100 Gallons Per Day
Model Number
AAA-504
AAA-754
AAA-1004
AAA4-MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AAA-124 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Applied Membranes AAA-124

  • Page 1 Under-The Counter 4 Stage Reverse Osmosis System System Flow Rate Model Number System Flow Rate Model Number 12 Gallons Per Day AAA-124 50 Gallons Per Day AAA-504 24 Gallons Per Day AAA-244 75 Gallons Per Day AAA-754 36 Gallons Per Day...
  • Page 2: Conditions For Operation

    Introduction Please read this entire service guide prior to beginning installation. The Applied Membranes reverse osmosis drinking water system has been designed for quick and simple installation and maintenance. By carefully reading this instruction manual and following the operational guidelines you will ensure a successful installation and reliable operation. Routine maintenance is essential to the longevity and performance of the system.
  • Page 3 Product Water – Final From the post-carbon outlet to the faucet Yellow Systems and Components Membranes, Filters, Chemicals 2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: sales@appliedmembranes.com Copyright © 2008 Applied Membranes, Inc. All Rights Reserved. Page 3...
  • Page 4: Preparing For Installation

    (additional tubing will be needed). The system will produce a faster flow at the faucet with the shortest tubing run from tank to faucet. Systems and Components Membranes, Filters, Chemicals 2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: sales@appliedmembranes.com Page 4 Copyright © 2008 Applied Membranes, Inc. All Rights Reserved.
  • Page 5: System Mounting

    With the collet held in this position the tube can be removed. The fitting can then be re-used. Systems and Components Membranes, Filters, Chemicals 2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: sales@appliedmembranes.com Copyright © 2008 Applied Membranes, Inc. All Rights Reserved. Page 5...
  • Page 6 Installation and Service Manual – Under-the-Counter 4 Stage Reverse Osmosis System Systems and Components Membranes, Filters, Chemicals 2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: sales@appliedmembranes.com Page 6 Copyright © 2008 Applied Membranes, Inc. All Rights Reserved.
  • Page 7: Starting Your Installation

    Systems and Components Membranes, Filters, Chemicals 2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: sales@appliedmembranes.com Copyright © 2008 Applied Membranes, Inc. All Rights Reserved. Page 7...
  • Page 8: Drain Saddle Installation

    Clean the debris from the pipe and the hole before continuing. Systems and Components Membranes, Filters, Chemicals 2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: sales@appliedmembranes.com Page 8 Copyright © 2008 Applied Membranes, Inc. All Rights Reserved.
  • Page 9 NOTE: Some states require the use of an air gap faucet. Check your local plumbing code to assure compliance. Systems and Components Membranes, Filters, Chemicals 2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: sales@appliedmembranes.com Copyright © 2008 Applied Membranes, Inc. All Rights Reserved. Page 9...
  • Page 10: Faucet Installation

    ” drill bits Faucet Assembly Kit Yellow Tubing (cut as per page 5) Systems and Components Membranes, Filters, Chemicals 2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: sales@appliedmembranes.com Page 10 Copyright © 2008 Applied Membranes, Inc. All Rights Reserved.
  • Page 11 Systems and Components Membranes, Filters, Chemicals 2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: sales@appliedmembranes.com Copyright © 2008 Applied Membranes, Inc. All Rights Reserved. Page 11...
  • Page 12: Connect Tubing

    This is normal and safe to drink. The air bubbles will disappear within a few days of regular use. Systems and Components Membranes, Filters, Chemicals 2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: sales@appliedmembranes.com Page 12 Copyright © 2008 Applied Membranes, Inc. All Rights Reserved.
  • Page 13: System Maintenance

    The post filter should be changed after sanitizing the system. Systems and Components Membranes, Filters, Chemicals 2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: sales@appliedmembranes.com Copyright © 2008 Applied Membranes, Inc. All Rights Reserved. Page 13...
  • Page 14: Troubleshooting Chart

    RO. Water should lose the milky look within a few days of normal usage. Systems and Components Membranes, Filters, Chemicals 2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: sales@appliedmembranes.com Page 14 Copyright © 2008 Applied Membranes, Inc. All Rights Reserved.
  • Page 15: Replacement Parts

    ¼”T x ¼”M Elbow Membrane Filter Bracket Fitting, Quick Connect Housing Clip (Filter In/Out) Systems and Components Membranes, Filters, Chemicals 2325 Cousteau Ct., Vista, CA 92081 USA • www.appliedmembranes.com • E-mail: sales@appliedmembranes.com Copyright © 2008 Applied Membranes, Inc. All Rights Reserved. Page 15...
  • Page 16: Product Warranty

    Product Warranty  SELLER hereby warrants to CUSTOMER that the goods herein described will be free from any liens or encumbrances, that good title to said goods will be conveyed to CUSTOMER by sale of same. SELLER warrants materials of its own manufacture against defects in material and workmanship under normal conditions of usage and service as specified in this manual for one year from whichever of the following events occur first: ...

This manual is also suitable for:

Aaa-504Aaa-244Aaa-364Aaa-754Aaa-1004

Table of Contents