5 Installation

5.1 Minimum clearance to
combustible surface
Cook top
A 200mm (Vertical combustible surface)
measured form the edge of the nearest
burner.
B 600mm (Overhead) measured form the
highest part of the highest surface and
750mm for an exhaust fan.
C 50mm (non-combustible surface)
D 20mm (benchtop)
X (width) & Y (depth) see appliance
dimension within this manual.
Refer to AS/NZS 5601 (Protection of a
combustible surface) if the above minimum
clearances cannot be achieved.
The top of the pan support is 9mm - 12 mm
above the bench top.
Refer to AS/NZS 5601
(Protection of a combustible
surface) if the above minimum
clearances cannot be achieved.
Maximum height of the top pan
support with respect to the surface
that supports the appliance is
40mm.
16
Installation
5.2 Gas connection
• After carrying out any operation, check
that the tightening torque of gas
connections is between 10 Nm and
15 Nm.
• If required, use a pressure regulator that
complies with current regulations.
• At the end of the installation, check for
any leaks with a soapy solution, never
with a flame.
Carefully screw the connector 3 to the
appliance's gas connector 1 (1/2" thread
ISO 228-1), placing the supplied seal 2
between them.
This appliance must be installed by an
authorised person in accordance with this
instruction manual, AS/NZS 5601.1 –
Gas installations (installation and pipe
sizing), local gas fitting regulations, local
electrical regulations, local health
regulations, Building Code of Australia and
any other government authority.
The appliance connection point
shall be accessible with the
appliance installed.
Gas leak
Danger of explosion