Generator Capacity; Power Management; Extension Cords - Westinghouse WGEN5300DFC User Manual

Dual fuel portable generator
Table of Contents

Advertisement

GENERATOR CAPACITY

DO NOT overload the generator's capacity. Exceeding
the generator's wattage/amperage capacity can damage
the generator and/or electrical devices connected to it.
Make sure the generator can supply enough continuous
(running) and surge (starting) watts for the items you will
power at the same time.
The total power requirements (Volts x Amps = Watts) of all
appliances connected must be considered. Appliance and
power tool manufacturers usually list rating information
near the model or serial number.
To determine power requirements:
1. Select the items you will power at the same time.
2. Total the continuous (running) watts of these items. This
is the amount of power the generator must produce
to keep the items running. See the wattage reference
chart.
3. Estimate how many surge (starting) watts you will need.
Surge wattage is the short burst of power needed to
start electric motor-driven tools or appliances such as a
circular saw or refrigerator. Because not all motors start
at the same time, total surge watts can be estimated by
adding only the item(s) with the highest additional surge
watts to the total rated watts from step 2.
Example:
Tool or Appliance
RV Air Conditioner (11,000 BTU)
TV (Tube Type)
RV Refrigerator
Light (75 Watts)
Coffee Maker
Total Starting Watts Needed
*Wattages listed are approximate. Verify actual wattage.
NOTICE
Running
Watts*
1010
300
180
Radio
200
300
600
2590 Total
Running
Watts*
Total Running Watts
Highest Starting Watts

POWER MANAGEMENT

To prolong the life of the generator and attached devices,
use care when adding electrical loads to the generator.
There should be nothing connected to the generator
outlets before starting the engine. The correct and safe
way to manage generator power is to sequentially add
loads as follows:
1. With nothing connected to the generator, start the
engine as described in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Tool or Appliance
Incandescent Lights
(4 Quantity x 75 Watts)
TV (Tube Type)
Sump Pump (1/3 hp)
Refrigerator or Freezer
Starting
Well Pump (1/3 hp)
Watts*
Furnace (1/2 hp)
1600
Radio
0
Drill (3/8", 4 amps)
600
Circular Saw
0
(Heavy Duty, 7-1/4")
0
Miter Saw (10")
0
Table Saw (10")
1600
*Wattages listed are approximate. Verify actual wattage.
Highest

EXTENSION CORDS

Starting
Watts*
2590
Asphyxiation hazard. Extension cords running directly
into the home increase the risk of carbon monoxide
+ 1600
poisoning through any openings. If an extension cord
4190
running directly into your home is used to power indoor
items, there is a risk of carbon monoxide poisoning to
people inside the home. ALWAYS use battery-powered
carbon monoxide detector (s) that meet current UL 2034
safety standards when running the generator. Regularly
check the detector (s) battery.
Westinghouse Outdoor Power Equipment, LLC | 19
OPERATION
Wattage Reference
Estimated
Running
Watts*
300
300
800
700
1000
800
200
440
1400
1800
2000
Estimated
Starting
Watts*
0
0
1300
2200
2000
2350
0
600
2300
1800
2000

Advertisement

Table of Contents
loading

Table of Contents