Components; Control Panel Components - Westinghouse WGEN5300DFC User Manual

Dual fuel portable generator
Table of Contents

Advertisement

COMPONENTS

CONTROL PANEL COMPONENTS

1
1. Fuel Selector Switch: Used to select gas or propane
operation.
2. Push Button START/STOP Switch: Push to once to
automatically start the engine. Push again to stop the
engine.
3. Battery Switch: Turns battery ON and OFF. Must be
ON before electric or remote start.
4. Main Circuit Breaker: The main circuit breaker
controls total output of all outlets to protect the
generator from overload or short circuit.
5. Voltage Selector Switch: Select 120 Volts or 240
Volts. Shut the generator OFF before switching
voltages.
6. 120/240 Volt AC, 30 Amp NEMA L14-30R Twist-
Lock Receptacle: Receptacle can supply a
maximum of 30 Amps
7. 120 Volt AC, 30 Amp NEMA TT-30R Receptacle:
Receptacle can supply a maximum of 30 Amps.
8. 120 Volt AC, 20 Amp Duplex NEMA 5-20R
Receptacles: Receptacles can supply a maximum of
20 Amps.
2
3
4
5
15
14
13
12
9. 20 Amp AC Circuit Breaker: Circuit breaker limits
10. 30 Amp AC Circuit Breaker: Circuit breaker limits
11. Ground Terminal: The ground terminal is used to
12. Smart Switch Outlet: Connects the Westinghouse
13. Battery Charging Port: Used to charge the battery
14. CO Sensor indicator lights: The CO Sensor
15. Battery Indicator: Indicates that power is ON. Light
COMPONENTS
6
7 7
11
10
the current that can be delivered through the NEMA
5-20R receptacles to 20 Amps.
the current that can be delivered through the TT-
30R receptacle to 30 Amps.
externally ground the generator.
ST Switch (sold separately) to the control panel.
with the included battery charger.
monitors for the accumulation of poisonous carbon
monoxide gas. If increasing levels of CO gas are
detected, the CO Sensor automatically shuts down
the engine
will remain illuminated while the unit is ON.