Troubleshooting

7.1 General information

SYMPTOMS
Display OFF
System and data display
in red (see page EN-15)
The unit cannot be
controlled via DMX
(inactivated wireless
DMX)
When using several units, dimming are
not synchronized
Light switches on when powered on
Light switches on when using the
control board
Strobe function doesn't work
Display
switches on
Display auto off mode activated
when button
is pressed
Display still off
when button
No power
is pressed
Problem with the DMX512
switched on
7
received signal and/or system
default
DMX protocol problem
Data display
7
switched on
Data cabling problem
in red
DMX address
Data display
7
switched on in
The strobe is active and the
green
channel value is void
Different Resolution
Different Smoothing
Different Dimming curve
Manual value is operating when
DMX is not connected
Use of the Focus mode
Strobe function inactive
Strobe function active
POSSIBLE REASONS
EN - 18 -
SOLUTIONS
Check the AUTO-OFF display in the
Fixture Setup
Check :
• power
• thermal protection
• the power supply connector must
be properly interlocked
Failure details are available in Fixture Setup
Check data signal
Check cabling and data
connectors
Check the DMX address
The value must be at 0 in order to have the
light intensity dimmed
All the units must have the same mode
Local values must be at zero
Section 4.1.2
Check that the selected mode allows the
strobe function
Control channel must be higher than 0
EN
The received
data protocol can
be checked in
the DMX Setup

Advertisement