Optics; Analysis; Led Reaction According To Led Temperature; Thermal Protection - Robert Juliat ROXIE Manual

300w led followspot
Table of Contents

Advertisement

Available languages

Available languages

6.1.5 Optics

The cleaning of optical parts (lenses) shall be carried out with solutions containing alcohol.

6.1.6 Analysis

If there is still a problem after the troubleshooting procedures (Cf. section 7),
contact RJ distributor with the following information:
• Model, version and serial number of the product.
• Software version (available in menu Fixture Status
• Description of the problem.

6.1.7 LED reaction according to LED temperature

LED temperature
5°C → 65°C
65°C → 75°C
75°C→ 90°C
LED intensity dims to zero output (overheating protection).
DMX and system LED feedback (7) is red and temperature is available in
Fixture Status menu.

6.1.8 Thermal protection

In case of thermal protection start :
• Remove the LED compartment (Cf. 6.1.4 ).
• Control possible overheating indications.
• Reassemble the LED compartment.
• Reset the thermal protection by pressing the button.

6.1.9 Adjusting the maximum light output level

The maximum intensity level of the LED source can be adjusted through the fixture setup
in order to have a consistent fixture fleet. The dimming level is then recalculated depending
on the limitation.

6.1.10 Exploded view / Spare parts list

Available on
Or on request through the Robert Juliat Service department
Lens tube access
Fan rotation at minimum level
Fan rotation increases progressively
Fan at maximum speed
LED intensity dims to zero output
(overheating protection)
DMX and system LED feedback (7) is red
www.robertjuliat.com
EN - 17 -
Version)
Fan
info@robertjuliat.fr
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Roxie211661166c

Table of Contents