OWNER’S MANUAL PORTABLE AIR CONDITIONER Model: CH-M10K7B F or proper operation, please read and keep this manual carefully. Designed by Cooper&Hunter International Corporation, Oregon, USA www.cooperandhunter.com...
Content Operation Notices The Refrigerant ......................1 Operation Environment ....................2 Safety Warning ......................3 Part's Name ......................4 Operation Guide Operation Introduction for Control Panel ..............5 Use for air conditioner .....................7 Using the remote control ..................8 Buttons on Remote Controller .................9 Introduction for Icons on Display Screen ..............9 Introduction for Buttons on Remote Controller ............10 Function Introduction for Combination Buttons .............13 Operation Guide ....................14...
Page 3
Explanation of Symbols Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
Appliance filled with flammable gas R32. Before install and use the appliance, read the owner’s manual first. Before repair the appliance, read the service manual first. The Refrigerant To realize the function of the air conditioner unit, a special refrigerant circulates in the system.
Operation Environment ● The air conditioner must be operated within the temperature range: 16°C ~ 35°C. ● The appliance is for indoor use only. ● The appliance must be positioned so that the plug is accessible. ● This air conditioner can only be used for family, not for commercial industry.
Safety Warning ● This appliance can be used by children aged from 8 years and above and persons with reduced physical,sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Operation Introduction for Control Panel Name of control panel Dual-8 nixie tube + / - button Cool mode indicator Health indicator(Optional) Dry mode indicator Fan mode indicator Heat mode indicator Cool&Heat Unit only Fan speed indicator Mode button Sleep button Timer button Fan button ON/OFF button...
Page 9
Operation Introduction for Control Panel Mode button Press this button and the mode will circulate according to below sequence: Cool→Dry→Fan→Heat Cool&Heat Unit only Cool: Under this mode, cooling mode indicator is bright. Dual-8 nixie tube displays set temperature. Temperature setting range is 16 °C~30°C. Dry: Under this mode, drying mode indicator is bright.
Use for air conditioner To change air flow direction 1. Up/down air flow direction • Hold the horizental louvers as shown in the diagram and adjust the air flow direnction. • Do not adjust the horizontal louvers to the lowest or the highest position in the COOL or DRY mode with the fan speed set to Low for an extended period of time, Condensation may form on the louvers.
Using the remote control This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
Buttons on remote controller ON/OFF button AUTO MODE button HEALTH X-FAN HUMIDITY +/- button FILTER TURBO FAN button HOUR ON/OFF button(Not applicable for this unit) button(Not applicable for this unit) ON/OFF HEALTH SAVE button MODE X-FAN button (Note: X-FAN is same with BLOW) TEMP button TIMER button TURBO button...
Introduction for buttons on remote controller Note: ● After putting through power, air conditioner will give out a sound and operation indicator " " is ON (red indicator). You can operate the air conditioner through the remote controller. ● At ON status, after each pressing button on remote controller, the signal icon " "...
Page 14
Introduction for buttons on remote controller Note: For preventing cold wind, after starting up heating mode, indoor fan will blow fan afterdelaying 1-5min. (Details time is decided by indoor ambient temperature) Temperature setting range on remote controller: 16℃ -30℃ . Fan speed setting range: auto, low speed, medium speed and high speed.
Page 15
Introduction for buttons on remote controller SAVE function: Under cool mode, press SAVE button and the unit will operate under SAVE mode. Dual-8nixie tube on remote controller displays "SE". Air conditioner will operate at auto speed. Set temperature can’t be adjusted. Press SAVE button again to exit SAVE mode.
Introduction for buttons on remote controller hour. When holding "+" or "-" button, 2s later, the time will change quickly until to Cancel TIMER OFF: Press "TIMER" button again under TIMER OFF status. ● At OFF status, press this button once can set TIMER ON. Please refer to TIMER off for detailed operation.
Operation guide 1. After putting through the power, press " " button on remote controller to ON/OFF turn on the air conditioner. 2. Press " " button to select your required mode: AUTO, COOL, DRY, FAN, MODE HEAT. 3. Press "+" or "-" button to set your required temperature. (Temperature can’t be adjusted under auto mode).
Clean and Maintenance WARNING: ● Before cleaning the air conditioner, please turn off the unit and disconnect power. Otherwise, it may cause electric shock. ● Do not wash air conditioner with water. Otherwise, it may cause electric shock. ● Do not use volatile liquid (such as thinner or gas) to clean the air conditioner. Otherwise, it may damage the appearance of air conditioner.
Page 19
Clean and Maintenance NOTICE dust in the operation environment, you can increase clean frequency. Clean heat discharge pipe Remove the heat discharge pipe from air conditioner, clean and dry it , and then reinstall it. (For the method of installation and removal , please refer to the instruction for "Installation and disassembly of heat discharge pipe").
Malfunction analysis Please check below items before asking for maintenance. If the malfunction still Phenomenon Troubleshooting Solution ● Power failure? ● Wait after power recovery. ● Is plug loose? ● Reinsert the plug. ● Whether the air switch is trip- ●...
Page 21
Malfunction analysis Phenomenon Troubleshooting Solution ● Whether air outlet or air inlet is ● Eliminate the obstacles. blocked? ● Under heating mode, whether ● The unit will stop blowing indoor temperature ireaches fan after reaching set set temperature? temperature. ● In order to prevent cold air, No fan blowed ●...
Page 22
Malfunction analysis Malfunction code 1. Pour out the water inside chassis. 2. If "H8" still exits, please contact professional Chassis is full of water. person to maintain the unit. Malfunction of ambient Please contact professional person to deal temperature sensor. with it.
Installation Precaution WARNING: ● Observe all governing codes and ordinances. ● Do not use damaged or non-standard power cord. ● Be caution during installation and maintenance. Prohibit incorrect operation to prevent electric shock, casualty and other accidents. Selection of installation location Basic requirement Installing the unit in the following places may cause malfunction.
Preparation before Installation NOTICE: Check if the accessories are available before installation. Accessory list joint A joint B joint C heat discharge pipe screw pipe clip rubber plug pipe hoop wire hook AUTO HEALTH X-FAN HUMIDITY FILTER TURBO HOUR ON/OFF ON/OFF MODE X-FAN...
Install Wire Hook ● Assemble the wire hook at the back of the unit with screws (the direction of wire direction of wire hook is upward wire hook screw direction of wire hook is downward ● Wind the power cord around the wire hook.
Removing Collected Water There are 2 ways to remove collected water: Use the continuous drainage option from the lower hole. NOTICE: When using the continuous drainage option from the bottom hole, install drainage pipe as follow before using, otherwise poor drainage will affect normal operation of the unit.
Page 27
Removing Collected Water ■ Drainage way as follows. 1. In Cool, Dry or Heat mode operating, the condensation water will be drained to the chassis. 2. When the chassis is full with water, the buzzer will give out 8 sounds and "H8" is displayed to remind user to discharge water: ●...
Page 28
Removing Collected Water Use the continuous drainage option from the middle hole NOTICE: Water can be automatically emptied into a floor drain by attaching 14mm inner diameter hose (not included). 1. Remove the continuous drain cap 1 by turning it counter clockwise then remove the rubber stopper 2 from the spout.
Installation in a double-hung sash window(Optional) 1. Connect the rain guards to the insect guard net. Insert all three projections on each rain guard into the holes in the insect guard net. Side “A” will now be at the top, as indicated in the diagram. Hole Insect guard net Rain guard...
Page 30
Installation in a double-hung sash window(Optional) The window panel cannot be installed in windows less than 20.5" (520mm) wide, as you will be unable to shut the exhaust cover. (1) Open the window sash and place the window panel on the window sill. (2) Secure the window panel to the window stool with screws.
Page 31
Installation in a double-hung sash window(Optional) 5. Close the window sash securely against the Window panel. 6. Stuff the sponge B between the glass and the window to prevent air and insects from getting into the room. 7. Attach the bracket with a screw.(Recommended) Bracket Please lay a tabular material underneath the window panel in case you could not attach the rain guard or the window adapter properly due to the deep...
Installation in a sliding sash window(Optional) 1. Connect the rain guards to the insect guard net. Insert all three projections on each rain guard into the holes in the insect guard net. Side “A” will now be at the top, as indicated in the diagram. "A"...
Page 33
Installation in a sliding sash window(Optional) The window panel cannot be installed in windows less than 20.5" (520mm) high, as you will be unable to shut the exhaust cover. (1) Open the window sash and place the window panel on the window frame. (2) Secure the window panel to the window frame with screws.
Page 34
Installation in a sliding sash window(Optional) 5. Close the window sash securely against the Window panel. 6. Stuff the sponge B between the glass and the window to prevent air and insects from getting into the room. 7. Attach the bracket with a screw.(Recommended) Bracket Please lay a tabular material underneath the window panel in case you could not attach the rain guard or the window adapter properly due to the deep...
Installation and Disassembly of Heat Discharge Pipe Install heat discharge pipe 1. Rotate joint A and joint B clockwise into the two ends of heat discharge pipe. clockwise clockwise joint A heat discharge pipe joint B+C 2. Insert joint A of heat clasp the side with "TOP"...
Page 36
Installation and Disassembly of Heat Discharge Pipe Note of Installingheat discharge pipe correct correct correct wrong ● The length of the heat discharge pipe is less than 1m. It is recommended to use it with shortest length. When installing,heat discharge pipe should be as flat as possible. Don’t prolong the pipe or connect it with other heat discharge pipe.
Page 37
Installation and Disassembly of Heat Discharge Pipe would easily cause malfunction.) Disassemble heat discharge pipe 1. Remove joint A: 2. Remove joint B+C from Press the clasp and lift joint A upwards to outdoors. remove it. clasp upwards disassemble joint A joint B+C...
Installation and Disassembly of Heat Discharge Pipe 3. Remove the window adapter. Pull out and remove the window adapter by pushing down two “PUSH” markings, and slide and close the exhaust cover in the window panel. (Optional) "PUSH" "PUSH" Operation Test ●...
Electric Schematic Diagram OUTTUBE TEMP. ROOM TEMP. TUBE TEMP. WATER MOTOR COLD PLASMA SENSOR SENSOR SENSOR RECEIVER POWER GENERATOR BN(BK) YEGN BOARD BU(WH) YEGN(GN) HEALTH-N HEALTH-L ROOM TUBE OUTTUBE WATER DISP2 AC-L DISP2 MAIN BOARD K201 COMP. YEGN DISP1 COMP COMP DISP1 R(M)
Page 40
Designed by Cooper&Hunter International Corporation, Oregon, USA www.cooperandhunter.com E-mail: info@cooperandhunter.com * Co o o o o o per & & Hu u nter is co o nstantly y w w w o o o rk k ing g to o im m m pro o o v v v e th h eir pro o o d d d u u u cts, so o th h e inf f f o o o rm m m atio o n in th h is m m m anu u al is su u u b b b j j j ect to o ch h ang g e w w ith h h o o o u u u t prio o r no o tice.