Summary of Contents for Cooper & Hunter Alpha NG Inverter Series

  • Page 1 OWNER’S MANUAL Split Air Conditioner Alpha NG Inverter Series M ODEL S : CHML-IW0 7 AARK CHML-IW09AARK CHML-IW12AARK CHML-IW18AARK CHML-IW24AARK E u r o p e D e s i g n CH 7-SKY SMART- Technology Filter For proper operation, please read and keep this manual carefully.
  • Page 2: Table Of Contents

    Content Operation Notices The Refrigerant......................1 Precautions......................2 Parts Name......................7 ScreenOperation Guide Buttons on remote controller .................9 Introduction for icons on display screen..............9 Introduction for buttons on remote controller ............10 Function introduction for combination buttons.............13 Operation guide ....................15 Replacement of batteries in remote controller .............15 Emergency operation ..................16 Maintenance Clean and Maintenance..................16...
  • Page 3 Explanation of Symbols Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
  • Page 4: The Refrigerant

    Please read this operating manual carefully before operating the unit. to the material objects for reference. The Refrigerant ● To realize the function of the air conditioner unit, a special refrigerant circulates leads to explosion . It can ● Compared to common refrigerants, R32 is a nonpolluting refrigerant with no lower.
  • Page 5: Precautions

    Precautions WARNING Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 6 Precautions WARNING Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner. Do not extend fingers or objects into air inlet or air outlet.
  • Page 7 Precautions WARNING Attachment Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Must follow the electric safety regulations when installing the unit. According to the local safety regulations, use qualified power supply circuit and circuit break. Do install the circuit break.
  • Page 8 Precautions WARNING Do not put through the power before finishing installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
  • Page 9 Precautions WARNING For the air conditioner with plug, the plug should be reachable after finishing installation. For the air conditioner without plug, an circuit break must be installed in the line. If you need to relocate the air conditioner to another place, only the qualified person can perform the work.
  • Page 10: Parts Name

    Parts Name Indoor Unit air inlet panel filter aux.button horizontal louver air outlet H O U R ONOFF (Display content or position may be different from above WiFi graphics, please refer to actual products) remote control NOTICE: Actual product may be different from above graphics, please refer to actual products.
  • Page 11 Parts Name Display For some model: temp. For some model: indicator heating cooling power receiver indicator indicator indicator window display cooling indicator receiver power window indicator heating temp. drying display drying indicator indicator indicator indicator For some model: For some model: drying indicator heating...
  • Page 12: Buttons On Remote Controller

    Buttons on remote controller ON/OFF button - button + button MODE button H O U R ONOFF FAN button SWING button I FEEL button button SLEEP button TEMP button TIMER-ON button CLOCK button TIMER-OFF button WiFi TURBO button LIGHT button WiFi button Introduction for icons on display screen X-fan...
  • Page 13: Introduction For Buttons On Remote Controller

    Introduction for buttons on remote controller Note: ● This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
  • Page 14 Introduction for buttons on remote controller FAN button This button is used for setting Fan Speed in the sequence that goes from AUTO, , to , then back to Auto. Auto High speed Low speed Medium speed ● X-FAN function Hold fan speed button for 2s in COOL or DRY mode, the icon “ ”...
  • Page 15 Introduction for buttons on remote controller SLEEP button Press this button to go into the SLEEP operation mode. Press it again to cancel this function. This function is available in COOL, HEAT (Only for models with heating function) mode to maintain the most comfortable temperature for you. TEMP button Press this button can see indoor set temperature, indoor ambient temperature or outdoor ambient temperature on indoor unit’s display.
  • Page 16: Function Introduction For Combination Buttons

    Introduction for buttons on remote controller TIMER-OFF button Press this button to initiate the auto-off timer. To cancel the auto-timer program, simply press the button again. TIMER OFF setting is the same as TIMER ON. TURBO button Press this button to activate / deactivate the Turbo function which enables the unitto reach the preset temperature in the shortest time.
  • Page 17 Function introduction for combination buttons Combination of "TEMP" and "CLOCK" buttons: About Energy-saving Function Press "TEMP" and "CLOCK" simultaneously in COOL mode to start energy-saving function. Nixie tube on the remote controller displays "SE". Repeat the operation to quit the function. Combination of "TEMP"...
  • Page 18: Operation Guide

    Operation guide After putting through the power, press "ON/OFF" button on remote controller to turn on the air conditioner. Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN, HEAT. Press "+" or "-" button to set your required temperature. (Temperature can’t be adjusted under auto mode).
  • Page 19: Emergency Operation

    Emergency operation If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below: air conditioner. When the air conditioner is turned on, it will operate under auto mode.
  • Page 20 Clean and Maintenance Open panel Pull out the panel to a certain ● Use dust catcher or water to the water (below 45℃ ) to clean it, and then put it in a shady and cool place to dry. panel cover tightly. WARNING operation environment, clean frequency can be increased.
  • Page 21 Clean and Maintenance NOTICE: Checking before use-season 1. Check whether air inlets and air outlets are blocked. 2. Check whether air switch, plug and socket are in good condition. 4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
  • Page 22: Malfunction Analysis

    Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the malfunction still Phenomenon Check items Solution ● Whether it's interfered severely ● Pull out the plug. Reinsert (such as static electricity, stable the plug after about 3min, and voltage)? then turn on the unit again.
  • Page 23 Malfunction analysis Phenomenon Check items Solution ● Power failure? ● Wait until power recovery. ● Is plug loose? ● Reinsert the plug. ● Air switch trips off or fuse is ● Ask professional to replace burnt out? air switch or fuse. Air condit- ●...
  • Page 24 Malfunction analysis Phenomenon Check items Solution ● Whether there’s odour source, ● Eliminate the odour source. Odours are such as furniture and cigarette, emitted etc. ● Whether there’s interference, ● Disconnect power, put back Air conditio- ner operates such as thunder, wireless power, and then turn on the abnormally devices, etc.
  • Page 25 Malfunction analysis Error Code ● When air conditioner status is abnormal, temperature indicator on indoor unit will ation of error code. Error code Troubleshooting It can be eliminated after restarting the unit. If not, please It can be eliminated after restarting the unit. If not, please It can be eliminated after restarting the unit.
  • Page 26: Safety Operation Of Flammable Refrigerant

    Safety operation of flammable refrigerant Qualification requirement for installation and maintenance man All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualification for dealing with the refrigeration system recognized by this industry. If it needs other technician to maintain and repair the appliance, they should be supervised by the person who bears the qualification for using the flammable refrigerant.
  • Page 27 Safety operation of flammable refrigerant a. Shut down the unit and cut power supply b. Eliminate the refrigerant c. Vacuuming d. Clean it with N2 gas e. Cutting or welding f. Carry back to the service spot for welding The refrigerant should be recycled into the specialized storage tank. Make sure that there isn’t any naked flame near the outlet of the vacuum pump and it’s well-ventilated.
  • Page 28: Installation Dimension Diagram

    Installation dimension diagram Space to the wall At least 15cm At least 15cm Space to the wall...
  • Page 29: Safety Precautions For Installing And Relocating The Unit

    Safety precautions for installing and relocating the unit To ensure safety, please be mindful of the following precautions. Warning When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant. Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture, resulting in injury.
  • Page 30: Tools For Installation

    Tools for installation 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note: ●...
  • Page 31: Requirements For Electric Connection

    Requirements for electric connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. air switch. 3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
  • Page 32: Installation Of Indoor Unit

    Installation of indoor unit Step one: choosing installation location rm it with the client. Step two: install wall-mounting frame 1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the plastic expansion particles in the holes. 3.
  • Page 33 Installation of indoor unit Indoor outdoor Note: ● Pay attention to dust prevention and take relevant safety measures when opening the hole. ● The plastic expansion particles are Φ55 not provided and should be bought 5-10 locally. Step four: outlet pipe 1.
  • Page 34 Installation of indoor unit Hex nut diameter Tightening torque (N . m) open-end wrench Φ 6 15~20 Φ 9.52 30~40 union nut Φ 12 45~55 pipe Φ 16 60~65 torque wrench Φ 19 70~75 indoor pipe 4. Wrap the indoor pipe and joint of con- nection pipe with insulating pipe, and then wrap it with tape.
  • Page 35 Installation of indoor unit 2. Make the power connection wire go cable-cross through the cable-cross hole at the back hole of indoor unit and then pull it out from the front side. power connection wire 3. Remove the wire clip; connect the power connection wire to the wiring terminal according to the color;...
  • Page 36 Installation of indoor unit Step eight: bind up pipe 1. Bind up the connection pipe, power drain hose connection pipe band cord and drain hose with the band. indoor and outdoor power cord indoor unit pipe indoor power cord liquid pipe 3.
  • Page 37: Check After Installation

    Check after installation Items to be checked Possible malfunction The unit may drop, shake or emit noise. Have you done the refrigerant leakage test? (heating) capacity. It may cause condensation and water dripping. It may cause condensation and water Is water drained well? dripping.
  • Page 38: Configuration Of Connection Pipe

    Configuration of connection pipe 1. Standard length of connection pipe ● 5m、7.5m、8m 2. Min length of connection pipe For the unit with standard connection pipe of 5m, there is no limitation for the min length of connection pipe. For the unit with standard connection pipe of 7.5m and 8m, the min length of connection pipe is 3m.
  • Page 39 Configuration of connection pipe Sheet 2. Additional refrigerant charging amount for R32 Diameter of connection pipe mm Indoor unit throttle Outdoor unit throttle Cooling only, cooling and Cooling only Liquid pipe Gas pipe cooling and heating heating (g / m) (g / m) (g / m) Ф6...
  • Page 40: Pipe Expanding Method

    Pipe expanding method Note: Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: A: Cut the pipe E: Expand the port ● Expand the port with expander. the distance of indoor unit and hard outdoor unit.
  • Page 41 * Cooper & Hunter is constantly working to improve their products, so the information in this manual is subj ect to change without prior notice. 66129929360...
  • Page 42 РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ Бытовой кондиционер Сплит система Серия Alpha NG Inverter МОДЕЛИ: CHML-IW0 7 AARK CHML-IW09AARK CHML-IW12AARK CHML-IW18AARK CHML-IW24AARK E u r o p e D e s i g n CH 7-SKY SMART- Technology Filter Пожалуйста, внимательно изучите данное руководство перед началом работы Designed by Cooper&Hunter International Corporation, Oregon, USA www.cooperandhunter.com...
  • Page 43 R32. R32, R32 - . R32 : «a» « » Space X.) R32.
  • Page 44 Меры предосторожности Пожалуйста, прочитайте следующее прежде, чем использовать оборудование! ПРЕДУПРЕЖДЕНИЕ ★ ★ ★ При появлении запаха Не касайтесь Предохраняйте от дыма немедленно оборудования повреждений обесточьте кондиционер мокрыми руками электрический кабель и и свяжитесь с сервисным кабель межблочной центром связи. Если изоляция кабеля...
  • Page 45 Меры предосторожности ★ Убедитесь, Для собственной ★ Устанавливайте ★ что оборудование безопасности отключайте наиболее подходящую надежно заземлено кондиционер от источника температуру питания перед обслуживанием, ремонтом и чисткой, а также если планируете не Установить темп. использовать его в помещении на 5 °С ниже, чем на длительное...
  • Page 46 Меры предосторожности ★ ★ Не используйте кабель со скрутками Для изменения направления и поврежденный кабель. Если кабель горизонтального воздушного потока поврежден, пожалуйста, свяжитесь с используйте пульт дистанционного сервисным центром для его замены управления Вертикальные Горизонтальные жалюзи жалюзи ★ ★ ★ Не...
  • Page 47 Название частей кондиционера Внутренний блок Вход воздуха ⑴ ⑶ ⑺ ⑺ ⑹ Выход воздуха ⑷ ⑸ Обозначения на дисплее H O U R ONOFF ON OF F ⑵ :Охлаждение MOD E SW I NG I FEE L :Осушение SLEE P TE M P TI MER - ON CLOCK T...
  • Page 48 Пульт управления ON/OFF(вкл/выкл) Нажмите для запуска и остановки работы Нажмите для понижения температуры Нажмите для повышения температуры MODE (режим) H O U R ONOFF Нажмите для выбора режима работы (AUTO/COOL/DRY/FAN/HEAT) FAN(вентилятор) Нажмите для изменения скорости вращения вентилятора SWING(жалюзи) Нажмите для изменения угла направления воздушного...
  • Page 49 Пульт управления SWING SLEEP Появляется при нажатии кнопки SWING. Отображает, что режим SLEEP активен. Горизонтальные жалюзи Нажмите еще раз, если хотите его выключить. Блокировка Появляется при одновременном нажатии LIGHT кнопок «+» и «-». Нажмите их еще раз, чтобы снять Появляется при нажатии кнопки LIGHT блокировку.
  • Page 50 Пульт управления CH SMART-ION FILTER CLOCK Появляется при нажатии кнопки Появляется при нажатии кнопки CLOCK. и активации режима. WIFI X-FAN Появляется при нажатии кнопк Появляется при нажатии кнопки X-FAN «WIFI». Функция «WIFI» предполагает включение и и активации режима. Для отключения нажмите кнопку еще раз. выключение...
  • Page 51 Пульт управления Описание пульта управления Нажмите кнопку для включения или выключения кондиционера. При ON/OFF включении кондиционера наЖК-дисплее внутреннего блока знак индикации « » горит зеленым цветом. Нажмите кнопку для понижения желаемой температуры в помещении. Удерживание кнопки,нажатой в течение 2 секунд, быстро понизит значение устанавливаемой...
  • Page 52 Пульт управления Описание пульта управления Нажмите кнопку для активации режима CH SMART-ION FILTER . Функция в данной моделе не реализована. вентиляции При нажатии на кнопку в первый раз отобразится функция вентиляции Если нажать второй раз, то отобразятся оба режима: . Третье нажатие и...
  • Page 53 Пульт управления Комбинация «+» и «-» Одновременное нажатие кнопок «+» и «–» блокируют кнопки пульта управления. На дисплее появляется значок . Повторное нажатие снимает блокировку. Комбинация MODE и «-» Одновременное нажатие кнопок MODE и «–» переключает единицы измерения температуры между градусами Цельсия и Фаренгейта. Комбинация...
  • Page 54 Аварийное включение Аварийное включение Если пульт дистанционного управления потерян или поврежден, вы можете воспользоваться кнопкой включения/выключения кондиционера, расположенной на внутреннем блоке под лицевой панелью. После включения кондиционер будет работать в режиме AUTO и менять скорость вращения вентилятора автоматически. Алгоритм работы кондиционера...
  • Page 55 Очистка и уход за оборудованием Внимание Отключите электропитание перед обслуживанием и ремонтом. Не брызгайте водой на блок для чистки из-за вероятности короткого замыкания. Протирайте блок сухой тряпкой или слегка влажной тряпкой, смоченной водой или легким раствором неагрессивного моющего средства. Не используйте растворители и абразивные моющие средства. Чистка...
  • Page 56 Очистка и уход за оборудованием Проверьте перед использованием ① Убедитесь, что ничего не мешает забору и подаче воздуха. ② Проверьте батарейки пульта управления. ③ Проверьте крепежные кронштейны наружного блока на отсутствие повреждений. Обслуживание перед использованием ① Отключите электропитание. ② Очистите фильтры и корпус наружного и внутреннего блоков. ③...
  • Page 57 Проблемы и их решения Внимание! Не ремонтируйте кондиционер самостоятельно. Для обслуживания и ремонта кондиционера обращайтесь в специализированные сервисные центры. Неправильный ремонт или обслуживание могут привести к короткому замыканию, пожару или поражению электрическим током. Пожалуйста, перед обращением в сервисный центр проверьте нижеприведенные моменты.
  • Page 58 Проблемы и их решения Явление Неисправность Блок не включается. Есть ли электропитание? Вставлена ли вилка в розетку? Не отключен ли автомат токовой защиты? Возможно, напряжение электропитания слишком низкое или высокое (это должны проверить специалисты). Проверьте, может быть, выставлена работа выключен автомат по...
  • Page 59 Проблемы и их решения Я в л е н и е Н е и п с р а в н о с ь т Нет подачи воздуха из внутреннего блока. В режиме обогрева, если температура теплообменника внутреннего блока слишком низкая, вентилятор не подает воздух в помещение, чтобы...
  • Page 60 Советы по эксплуатации Охлаждение Описание Кондиционер воздуха забирает тепло в помещении и отводит через наружный блок, таким образом понижая температуру в помещении. Текущая холодопроизводительность зависит от температуры наружного воздуха. Защита от обмерзания Если кондиционер работает в режиме охлаждения при низкой температуре окружающего воздуха, теплообменник...
  • Page 61 Советы по эксплуатации Энергосбережение Не допускайте перегрева и переохлаждения. Устанавливайте желаемую температуру в диапазоне, который может помочь снизить энергозатраты. Закрывайте окна и шторы. Солнечные лучи и воздух, попадающий через открытые двери, снижает эффективность охлаждения (нагрева). Очищайте воздушные фильтры каждые 2 недели. Грязные...
  • Page 62 Прочтите перед установкой Внимание! 1. Оборудование должно устанавливаться специалистами, имеющими соответствующие лицензии и сертификаты, строго соблюдая все требования и нормы безопасности, а также требования данной инструкции. 2. Перед установкой обратитесь в местное представительство торговой марки или авторизованную компанию-установщик. Если оборудование было установлено неавторизованной компанией, то ошибки...
  • Page 63 Прочтите перед установкой Выбор места установки внутреннего блока 1. Убедитесь, что ничего не препятствует входящим и исходящим потокам воздуха кондиционера. 2. Выберите место, где сконденсированная вода будет отводиться беспрепятственно и легко. выполнить соединения с наружным блоком. 3. Выберите место, недоступное детям. 4.
  • Page 64 Прочтите перед установкой Автомат токовой Модель кондиционера защиты 10 A 16 A 18-24 25 A Примечание: 1. Убедитесь в надежности подключения кабеля питания и заземления. убедитесь, что выполненное подключение соответствует электросхеме. 2. Ошибка в подключении может привести к короткому замыканию или пожару. Требования...
  • Page 65 Схема установки Схема установки Расстояние до потолка Более 15 см Расстояние до стены Более 15 см Более 15 см Расстояние до стены Сторона выхода воздуха Расстояние до пола Расстояния необходимые для правильного выбора места установки оборудования, включающие минимальные расстояния до препятствий Расстояние...
  • Page 66 Установка внутреннего блока Установка монтажной пластины 1. Монтажная пластина должна быть установлена строго горизонтально. Это важно, т.к. в конструкции блока предусмотрен наклон ванночки нормального отвода конденсата. Если блок не установлен горизонтально, конденсат может не отводиться правильно. 2. Закрепите монтажную пластину на стене при помощи винтов и дюбелей. 3.
  • Page 67 Проверка после установки перед первым пуском Проверка после установки Что проверить Возможные неисправности Блок может упасть, издавать шум или Блок надежно установлен? вибрацию Снижается эффективность работы Отсутствуют утечки хладагента? Конденсат может протекать Надежна теплоизоляция? Конденсат отводится нормально? Возможны протечки Электропитание соответствует Возможен...
  • Page 68 Установка и обслуживание дополнительного фильтра Установка опционального фильтра Одновременно с двух сторон подденьте пальцами и откройте лицевую панель. Затем вытащите воздушные фильтры как показано на рис. а Рис. a Рис. б Вставьте опциональный фильтр в Фильр специальные пазы на воздушном фильтре как...
  • Page 69 Designed by Cooper&Hunter International Corporation, Oregon, USA www.cooperandhunter.com E-mail: info@cooperandhunter.com * Cooper&Hunter постоянно работает над улучшением своей продукции, поэтому информация приведенная в данном руководстве, может быть изменена без предварительного уведомления потребителей. 66160000078...