OPERATING INSTRUCTIONS
DSJ-50E-01A
Capacity Rated Using Department of Energy Test Procedure
Dehumidifier must be upright for 24 hours prior to operating.
This ensures that the compressor will function as intended.
25 Pint
DSJ-25E-01
35 Pint
DSJ-35E-01
50 Pint
600538
V211222

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DSJ-25E-01 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Soleus Air DSJ-25E-01

  • Page 1 Portable Dehumidifier OPERATING INSTRUCTIONS 25 Pint DSJ-25E-01 35 Pint DSJ-35E-01 50 Pint 600538 DSJ-50E-01A V211222 Capacity Rated Using Department of Energy Test Procedure Dehumidifier must be upright for 24 hours prior to operating. This ensures that the compressor will function as intended.
  • Page 2: Purchase Information

    PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable Dehumidifier. This Owner’s Manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Portable Dehumidifier.
  • Page 3 Maximum number of times to Model Number Pints of moisture removed per empty the bucket when operating 24 hour period (DOE Rating) at full capacity during a 24 hour period DSJ-25E-01 25 Pints 3 Times DSJ-35E-01 35 Pints 4 Times DSJ-50E-01A...
  • Page 4: Package Contents

    PACKAGE CONTENTS (1) Portable Dehumidifier (1) Operating Instructions SPECIFICATIONS Model Number DSJ-25E-01 DSJ-35E-01 DSJ-50E-01A Dehumidifying Capacity 25 Pints per day 35 Pints per day 50 Pints per day (DOE Rating) Power Consumption 295 Watts 370 Watts 525 Watts (Watts) Air Flow Volume...
  • Page 5: Product Features

    PRODUCT FEATURES Removes up to 25/35/50 pints (depending on model) of moisture from the air every 24 hours. This is not the bucket size. Adjustable humidistat for precise humidity control. Mirage Display shows ambient humidity level from across the room. Operates at temperatures down to 41°F.
  • Page 6: Control Panel

    CONTROL PANEL Digital Humidistat POWER Display Child-Lock BUTTON Bucket Full LED Indicator LED Indicator MyHome Mode Clean Filter Fan Speed Power On Timer LED Indicators LED Indicator LED Indicators LED Indicator LED Indicator FILTER PRESET MIRAGE TIMER INCREASE/DECREASE BUTTON SPEED MODE DISPLAY ROOM...
  • Page 7 OPERATING INSTRUCTIONS Dehumidifier must be upright for 24 hours prior to operating. This ensures that the compressor will function as intended. CONTROL PANEL OPERATING INSTRUCTIONS 1) When first operating the dehumidifier, run it in Continuous mode for 24 hours. 2) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER but- ton once more to turn the unit off.
  • Page 8 OPERATING INSTRUCTIONS 8) Bucket Full - When the water bucket completely fills with water, the unit will automatically shut off, make an audible beep, and the Bucket Full Indicator will light up. The dehumidifier will not function until the wa- ter bucket is emptied and placed back inside the unit.
  • Page 9: Choosing A Location

    CHOOSING A LOCATION A Dehumidifier operating in a basement will have little or no effect in drying out an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area. Do not use outdoors.
  • Page 10: Continuous Drainage

    CONTINUOUS DRAINAGE Garden Hose Installation Setup Water can be automatically emptied by attaching a garden hose to the continuous drainage port on the back of the dehumidifier. This will allow the unit to run continuously (depending on the selected humidity level) with- out having to empty the water bucket.
  • Page 11: Maintenance

    MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an elec- trical outlet prior to performing any maintenance on the unit. Clean or Replace Filter - The Clean Filter indicator will illuminate every 250 hours of operation as a reminder to clean the filter.
  • Page 12: Troubleshooting

    TROUBLESHOOTING Problem Possible Causes Solutions Dehumidifier does not start The dehumidifier is unplugged. Make sure the dehumidifier’s plug is pushed completely into the outlet. The fuse is blown / circuit break- Check the house fuse / circuit breaker box and replace fuse or er is tripped.
  • Page 13 TROUBLESHOOTING Problem Possible Causes Solutions Water on the floor Hose connection may be loose. Check the hose connection. See the CONTINUOUS MODE- GARDEN HOSE INSTALLATION AND SET UP Section on Page 10. Hose is attached but not draining Disconnect the hose if using the bucket or place the hose near into a drain.
  • Page 14 SELF-DIAGNOSING CODES Self- Diagnosing Description Resolution Code Compressor Overheat Protection Please call Customer Service at (833) 669-9998 Condenser Overheat Protection Humidity Sensor Malfunction For any questions or Technical Support, please call customer ser vice (833) 669-9998...
  • Page 15: Limited Warranty

    LIMITED WARRANTY One Year Limited Warranty JHS INC. warrants the accompanying Dehumidifier to be free of defects in material and workmanship for the applica- tions specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States.