Soleus Air iCongo DS1-30-01 Operating Instructions Manual

Soleus Air iCongo DS1-30-01 Operating Instructions Manual

30 pints/45 pints/70 pints portable dehumidifier
Hide thumbs Also See for iCongo DS1-30-01:

Advertisement

30 Pints/45 Pints/70 Pints
Portable Dehumidifier
Operating Instructions
Model No.: DS1-30-01
DS1-45E-101
DS1-70E-101
3058080
V160328

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iCongo DS1-30-01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Soleus Air iCongo DS1-30-01

  • Page 1 30 Pints/45 Pints/70 Pints Portable Dehumidifier Operating Instructions Model No.: DS1-30-01 DS1-45E-101 DS1-70E-101 3058080 V160328...
  • Page 2 General Dehumidifier Information RECOMMENDED HUMIDITY LEVELS  Spring/Summer: 35% - 50%  Fall/Winter: 35% - 40% WARM AIR EXHAUST IS NORMAL During operation your dehumidifier will exhaust warm air from the side of the unit. This is normal operation. EMPTYING THE BUCKET The more moisture your dehumidifier removes from the air, the more often you may have to empty the bucket (unless you are using the continuous drainage option).
  • Page 3 FEATURES Removes up to 30/45/70 pints (depending on model) of moisture from the air every 24 hours depending on the unit you have. This is not the bucket size. Adjustable humidistat for precise humidity control. Digital humidistat displays set humidity level and current room humidity level.
  • Page 4: Important Instructions

    Thank you for choosing a Soleus Air Portable Dehumidifier. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the opera- tional aspects of your new Dehumidifier.
  • Page 5: Package Contents

    PACKAGE CONTENTS (1) Portable Dehumidifier (1) Operating Instructions (4) Casters (1) Bucket Handle SPECIFICATIONS  Noise level is measured at a distance of 3.28 ft away from the front of the unit.  Power consumption is measured when the fan runs at the highest speed setting. ...
  • Page 6: Caster Installation

    CASTER INSTALLATION 1) Remove casters from the bucket. 4 casters in For the 70 Pint, the four casters can be taken out from the side plastic bag packed inside of the bucket directly. (Fig. 1) bucket For the 30 Pint and 45 Pint, please check if the casters are under the lid of the bucket.
  • Page 7 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) When first operating the dehumidifier, run it in Continuous mode for 24 hours. 2) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off. 3) Humidity Selection - Press the buttons to...
  • Page 8 OPERATING INSTRUCTIONS 6) Bucket Full - When the water bucket is full of water, the unit will automatically shut off , make a beeping noise, and the Bucket Full Indicator will light up. The dehumidifier will not function until the water bucket is emptied and placed back inside the unit.
  • Page 9 OPERATING INSTRUCTIONS 7) Clean Filter - When the filter needs to be cleaned, the filter indicator will light up (after 250 hours of use). Remove the filter from the back of the unit by using your thumbs to press down on the filter tabs directly above the filter.
  • Page 10: Choosing A Location

    CHOOSING A LOCATION A Dehumidifier operating in a basement will have little or no effect in drying out an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area. ...
  • Page 11: Continuous Mode-Garden Hose Installation And Setup

    CONTINUOUS MODE—GARDEN HOSE INSTALLATION AND SETUP Water can be automatically emptied by attaching a hose to the continuous drainage port on the back of the dehumidifier. This will allow the unit to run continuously (depending on the selected humidity level) without having to empty the water bucket. To drain, simply attach a standard garden hose (not included).
  • Page 12: Maintenance

    MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an elec- trical outlet prior to performing any maintenance on the unit. Clean or Replace Filter - Refer to Page 9 Operating Instructions Clean Filter section. Clean the Unit Housing - 1) Keep the unit from being exposed directly to the sun to prevent color fading.
  • Page 13: Troubleshooting

    TROUBLESHOOTING Problem Possible Causes Solutions Dehumidifier does not start The dehumidifier is unplugged. Make sure the dehumidifier’s plug is pushed completely into the outlet. The fuse is blown / circuit Check the house fuse / circuit breaker box and replace fuse or breaker is tripped.
  • Page 14 TROUBLESHOOTING Problem Possible Causes Solutions Water is on the floor End of Season drain plug is loose Check inside the bucket cavity on the unit and be sure that the rubber drain plug is completely inserted. The fuse is blown / circuit Check the house fuse / circuit breaker box and replace fuse or breaker is tripped.
  • Page 15 SELF-DIAGNOSING CODES Self- Diagnosing Description Resolution Code Compressor Overheat Protec- Please call Soleus Customer Service at 877-976-5387. tion Please call Soleus Customer Service at 877-976-5387. Condenser Overheat Protection Please call Soleus Customer Service at 877-976-5387. Humidity Sensor Malfunction For any questions or Technical Support, please call customer service (8 )
  • Page 16: Warranty

    One Year Limited Warranty Soleus Home Comfort warrants the accompanying Soleus Air Dehumidifier to be free of defects in material and work- manship for the applications specified in its operation instruction for a period of specified below from the date of original retail purchase in the United States.

This manual is also suitable for:

Icongo ds1-45e-101Icongo ds1-70e-101

Table of Contents