Example:
1
LC
4
04
5
E
A
10
T
3.2

Data table

Maximum utilisation pressure
Maximum operating pressure
Maximum suction pressure
Notice: the suction pressure (P input) + the pressure at
zero delivery rate (P zero delivery rate) must always be
lower than the maximum authorised operating pressure
(P max). P input + P zero delivery rate ≤ P max. Refer to
the pump rating plate for the maximum operating pres-
sure: P max.
Temperature range
Fluid temperature
Ambient temperature
Electrical data
Motor protection rating
Insulation class
Frequency
Voltage
Motor efficiency
Other characteristics
Humidity
Altitude
Motor power (kW)
0.37
0.55
0.75
22
Product information
Medana CH1-LC.404-5/E/A/10T
Series level (1 = entry level, 3 = standard level, 5 = premium level)
L = Long shaft
C = Pump housing in cast iron
3
Delivery rate in m
/h
Number of impellers
Pump housing in cast iron + hydraulics in 1.4307 stainless steel
EPDM seal
A = Frequency 50 Hz / single-phase / 230 V
B = Frequency 60 Hz / single-phase / 220 V
C = Frequency 60 Hz / single-phase / 230 V
D = Frequency 50 Hz / three-phase / 400 V
E = Frequency 50 Hz / three-phase / 230 – 400 V
F = Frequency 60 Hz / three-phase / 220 – 380 V
G = Frequency 60 Hz / three-phase / 265 – 460 V
I = Frequency 60 Hz / three-phase / 460 V
Maximum pressure of the pump in bar
Screwed connections
See pump type key on rating plate and paragraph 3.1
6 bar
-20 °C to +120 °C with EPDM seals
-20 °C to +90 °C with VITON seals
(only on version L)
-15 °C to +50 °C
See plate
See plate
See plate
See plate
See plate
< 90 % without condensation
≤ 1000 m (> 1000 m on request)
Noise level
Frequency (Hz)
50
50
50
Phase
dB(A) at 1 m, BEP tolerance
0 – 3 dB(A)
3
3
3
54
54
55