Wilo Medana CH1-LSP Installation And Operating Instructions Manual

Wilo Medana CH1-LSP Installation And Operating Instructions Manual

Advertisement

Quick Links

Pioneering for You
Wilo-Medana CH1-LSP
en Installation and operating instructions
·
4263617 • Ed.01/08/2023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Medana CH1-LSP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wilo Medana CH1-LSP

  • Page 1 Pioneering for You Wilo-Medana CH1-LSP en Installation and operating instructions · 4263617 • Ed.01/08/2023...
  • Page 3 Fig. 1 Fig. 2 Fig. 3a Fig. 3b...
  • Page 4 Fig. 3c Fig. 4 Fig. 5...
  • Page 5 Fig. 6 Fig. 7 Fig. 8...
  • Page 7: Table Of Contents

    Receipt of the product ............ 13 Installation ................ 13 Hydraulic connections............ 14 Electrical connection ............ 15 8 Commissioning ................. 15 Filling and deaeration ............ 15 Starting................. 16 9 Maintenance................ 17 10 Faults, causes and remedies............ 18 11 Spare parts ................ 19 12 Disposal .................. 19 Installation and operating instructions • Wilo-Medana CH1-LSP • Ed.01/08/2023...
  • Page 8: General

    All rights reserved. Subject to modifications Wilo reserves the right to change the above-listed data without prior notice and is not li- able for technical inaccuracies and/or omissions. The figures used may differ from the ori- ginal product and are intended for illustrative purposes only.
  • Page 9: Personnel Qualifications

    Children must be supervised to ensure that they do not play with the device. • If hot or cold components of the product or installation pose a danger, it is the customer’s responsibility to guard them against being touched. Installation and operating instructions • Wilo-Medana CH1-LSP • Ed.01/08/2023...
  • Page 10: Safety Instructions For Installation And Maintenance Work

    (humidity, frost etc.). Temperature range for transport and storage: -30 °C to +60 °C. Handle the product with care so as not to damage it prior to installation. Installation and operating instructions • Wilo-Medana CH1-LSP • Ed.01/08/2023...
  • Page 11: Application

    B = 1~220 V, 60 Hz E = 3~230/400 V, 50 Hz Maximum pressure of the pump in bar Connections T = Screwed P = Victaulic N = With captive nut Data table Maximum utilisation pressure Installation and operating instructions • Wilo-Medana CH1-LSP • Ed.01/08/2023...
  • Page 12: Scope Of Delivery

    Drainage screw Stage casing Impeller Hydraulic shaft Pump housing Mechanical seal 10. Terminal box 11. Lantern 12. Condensate plugs See Fig. 3a Valve on the suction side Valve on the discharge side Installation and operating instructions • Wilo-Medana CH1-LSP • Ed.01/08/2023...
  • Page 13: Product Characteristics

    In this case, the motor protection class IP55 will no longer be guaranteed. • Note that the altitude of the installation site and the water temperature will reduce the suction capacity of the pump. Installation and operating instructions • Wilo-Medana CH1-LSP • Ed.01/08/2023...
  • Page 14: Hydraulic Connections

    (Fig. 3b). • Air must not be allowed to enter the suction piping while the pump is in operation. Installation and operating instructions • Wilo-Medana CH1-LSP • Ed.01/08/2023...
  • Page 15: Electrical Connection

    Filling and deaeration WARNING Risk of infection Our pumps may be factory-tested to verify their hydraulic performance. If some water remains, the pump should be rinsed before use for hygiene reasons. Installation and operating instructions • Wilo-Medana CH1-LSP • Ed.01/08/2023...
  • Page 16: Starting

    The pump must not be operated at a zero flow rate flow (valve on the discharge side closed) for more than 10 minutes. We recommend maintaining a minimum discharge of 15% of rated dis- charge. Installation and operating instructions • Wilo-Medana CH1-LSP • Ed.01/08/2023...
  • Page 17: Maintenance

    WARNING Risk of burns In case of high water temperatures and high system pressures, close the guard valves upstream and downstream of the pump. First, allow pump to cool down. Installation and operating instructions • Wilo-Medana CH1-LSP • Ed.01/08/2023...
  • Page 18: Faults, Causes And Remedies

    Suction pipe too narrow Install wider suction pipe The pump discharges irregularly The pressure at the pump inlet is insufficient Review the installation conditions and recom- mendations described in this manual Installation and operating instructions • Wilo-Medana CH1-LSP • Ed.01/08/2023...
  • Page 19: Spare Parts

    If the fault cannot be resolved, please contact the Wilo customer service. Spare parts All spare parts should be ordered directly from the Wilo customer service. To prevent errors, always quote the data on the pump’s rating plate when making an order. The spare parts catalogue is available at www.wilo.com...