Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Pioneering for You
Wilo-Crono... IL/DL/BL
Wilo-Vero... IPL-N/DPL-N, IPS
de Zusatzanleitung ATEX
en Supplementary instructions ATEX
fr
Notice complémentaire ATEX
nl
Extra handleiding ATEX
2 140 021-Ed.01 / 2013-10-Wilo

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Crono Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Wilo Crono Series

  • Page 1 Pioneering for You Wilo-Crono... IL/DL/BL Wilo-Vero... IPL-N/DPL-N, IPS de Zusatzanleitung ATEX en Supplementary instructions ATEX Notice complémentaire ATEX Extra handleiding ATEX 2 140 021-Ed.01 / 2013-10-Wilo...
  • Page 3 Zusatz-Einbau- und Betriebsanleitung ATEX Additional installation and operating instructions ATEX Notice de montage et de mise en service complémentaire ATEX Extra inbouw- en bedieningsvoorschriften ATEX...
  • Page 4: Table Of Contents

    Elektrischer Anschluss ............................12 Erdung..................................12 Trockenlaufschutz..............................12 Probelauf mit Produkt............................12 Hinweise zum Betrieb .........................12 Unzulässige Betriebsweisen ..........................12 Explosionsschutz ..............................12 Hinweise zur Wartung .........................15 Motorlager ................................16 Statische Dichtungen ............................16 Kupplungsschutz ..............................16 Gleitringdichtung..............................16 Freigängigkeit der Antriebswelle ........................16 Laufrad der Baureihe Wilo-VeroLine-IPS......................16 WILO SE 10/2013...
  • Page 5: Allgemeines

    Schadensfall, wenden Sie sich bitte an den Service-International der Wilo SE. Kennzeichnung von Hinweisen in der Betriebsanleitung Symbole Allgemeines Gefahrensymbol Gefahr durch elektrische Spannung Besonderer Sicherheitshinweis in Hinblick auf den Explosions- schutz HINWEIS Zusatz-Einbau- und Betriebsanleitung ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 6: Personalqualifikation

    Symbol gekennzeichneten Abschnitte dieser Zusatz-Einbau- und Betriebsanleitung besonders zu beachten. Sicherheitshinweise für den Wilo-Geräte sind nicht dafür bestimmt, durch Personen (einschließ- Betreiber lich Kinder) mit eingeschränkten physischen, sensorischen oder geis- tigen Fähigkeiten oder mangels Erfahrung und/oder mangels Wissen benutzt zu werden, es sei denn, sie werden durch eine für ihre Sicher-...
  • Page 7: Sicherheitshinweise Für Montage- Und Wartungsarbeiten

    Flüssigkeit elektrostatisch aufgeladen wird und hier- durch Zündgefahren auftreten. • Es sind entsprechende Vorsichtsmaßnahmen zu treffen, siehe Kapitel 6.4 „Erdung“ auf Seite 11 und Kapitel 8.3 „Kupplungs- schutz“ auf Seite 16. Zusatz-Einbau- und Betriebsanleitung ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 8: Transport Und Zwischenlagerung

    Aufgrund der dabei möglichen Drehzahlen besteht die Gefahr einer Überhitzung und damit einer Überschreitung des zulässigen Tem- peraturbereichs. • Die Betriebsbedingungen sowie die zulässigen Fördermedien sind dem folgenden Kapitel 5.2 „Zulässige Betriebsverhältnisse“ auf Seite 8 dieser Betriebsanleitung zu entnehmen. WILO SE 10/2013...
  • Page 9: Angaben Über Die Erzeugnisse Und Betriebsverhältnisse

    Kapitel 7 „Hinweise zum Betrieb“ auf Seite 12). Die Pumpe darf nicht gegen geschlossene Ventile, Blenden, Schie- ber oder sonstige Absperrorgane im Medienkreislauf betrieben werden. Bei Nichtausschluss muss eine Volumenstromüberwa- chung installiert werden. Zusatz-Einbau- und Betriebsanleitung ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 10: Zulässige Betriebsverhältnisse

    Kühlwasser mit Frostschutz Standard 2 und 4 (pH-Wert: 7,5-10; keine (AQ1EGG) 40 °C 40 °C verzinkten Bauteile) Wasser-Glycol-Gemisch Standard 2 und 4 40 °C 40 °C (20 %-40 % Glycol) (AQ1EGG) Tab. 2: Zulässige Betriebsverhältnisse für die Baureihe IPL-N/DPL-N WILO SE 10/2013...
  • Page 11 40 °C 40 °C verzinkten Bauteile) Wasser-Glycol-Gemisch Standard 2 und 4 40 °C 40 °C 40 °C 40 °C (20 %-40 % Glycol) (AQ1EGG) Tab. 3: Zulässige Betriebsverhältnisse für die Baureihe IL/DL/BL Zusatz-Einbau- und Betriebsanleitung ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 12 • Explosionsschutzverordnung (ExVO) • Gefahrstoffverordnung (GefStoffV, gemäß Richtlinie 98/24/EG) Beim Einsatz der Pumpe ist darauf zu achten, dass - wie bei allen Umwälzprozessen mit brennbaren Flüssigkeiten - die Möglichkeit der elektrostatischen Aufladung der Flüssigkeit besteht. Hierdurch können Zündgefahren auftreten. WILO SE 10/2013...
  • Page 13: Betrieb Mit Brennbaren Flüssigkeiten Und Explosionsschutz

    Es sind unbedingt die Hinweise im Kapitel 7.2.1 „Füllen/Entlüften der Pumpe“ auf Seite 12 zu berücksichtigen! Es sind die Hinweise in der Betriebsanleitung zur Pumpenbaureihe zur Inbetriebnahme, speziell zur Entlüftung der Pumpe, zu berück- sichtigen! Zusatz-Einbau- und Betriebsanleitung ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 14: Probelauf Mit Produkt

    Beim Betrieb der Pumpe wird davon ausgegangen, dass das System der Saug- und Druckleitung und damit der flüssigkeitsberührte Innenraum der Pumpe einschließlich Dichtungsraum ständig mit Förderflüssigkeit gefüllt ist, so dass dort keine explosionsfähige Atmosphäre vorliegen kann. Kann der Betreiber dies nicht sicherstellen, so sind entsprechende WILO SE 10/2013...
  • Page 15 VORSICHT! Gefahr von Sachschäden! Gefahr der Beschädigung der Pumpe durch zu niedrige Medientem- peraturen! • Für Pumpen der Baureihe Wilo-VeroLine-IPS gilt, dass eine Min- desttemperatur des Mediums von -10 °C auch bei extremen Umge- bungstemperaturen nicht unterschritten werden darf! 7.2.3 Betriebsweise der Pumpe Es ist sicherzustellen, dass die Pumpe stets mit voll geöffnetem saug-...
  • Page 16 (z.B. durch Gehörschutz, Warnhinweise usw.). Der Dauerschalldruckpegel ist an den Bedien-, Überwachungs- bzw. Wartungsplätzen zu messen. 7.2.6 Bauliche Veränderungen an der Alle Umbauten bedürfen einer schriftlichen Genehmigung von Wilo. Maschine VORSICHT! Gefahr von Sachschäden! Eine einwandfreie Funktion der Pumpe kann nur gewährleistet werden, wenn Originalersatzteile verwendet werden.
  • Page 17: Hinweise Zur Wartung

    • Schraubverbindungen auf festen Sitz kontrollieren, Anzugsmomente beachten. Nach Beendigung der Wartungsarbeiten Sicherheitseinrichtungen auf Funktion überprüfen. Wilo empfiehlt, bei erstmaligen Reparaturen an der Pumpe Wilo-Per- sonal in Anspruch zu nehmen. Gleichzeitig kann hierbei Ihr Wartungs- personal geschult werden. Wilo empfiehlt ferner die Aufstellung eines Wartungsplanes.
  • Page 18: Motorlager

    Schleifen oder Blockieren des Laufrads hindeuten könnten. Laufrad der Baureihe Aufgrund des verwendeten Werkstoffes muss bei Pumpen der Bau- Wilo-VeroLine-IPS reihe Wilo-VeroLine-IPS das Laufrad nach einer Betriebszeit von 8 Jahren gewechselt werden. Technische Änderungen vorbehalten! WILO SE 10/2013...
  • Page 19 Motor bearings ..............................31 Static gaskets ..............................31 Coupling protection ............................31 Mechanical seal ..............................31 Unobstructed movement of the drive shaft ....................31 Wilo-VeroLine-IPS series impellers ........................31 Supplementary installation and operating instructions ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 20: General

    – also with respect to any installation person- nel called in. In the event that additional information or instructions are required, as well as in case of damage, please contact the International Service Department at WILO SE. Indication of instructions in the operating instructions Symbols...
  • Page 21: Personnel Qualifications

    Safety instructions for the operator Wilo devices are not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of expe- rience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 22: Safety Instructions For Installation And Maintenance Work

    • Implement corresponding precautionary measures, see chapter 6.4 “Earthing” on page 26 and chapter 8.3 “Coupling protection” on page 31. WILO SE 10/2013...
  • Page 23: Transport And Interim Storage

    • Both operating conditions and permitted fluids can be found in the following chapter 5.2 “Authorised operating conditions” on page 23 of these installation and operating instructions. Supplementary installation and operating instructions ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 24: Specifications Concerning Products And Operating Conditions

    7 “Operating instructions” on page 27). The pump may not be operated against closed valves, orifice plates, slide valves or other check valves in the media circulation. If these cannot be excluded, then a volume flow monitor must be installed. WILO SE 10/2013...
  • Page 25: Authorised Operating Conditions

    40 °C 7.5-10; no galvanised components) Water-glycol mixture Standard 2 and 4 40 °C 40 °C (20 %-40 % glycol) (AQ1EGG) Tab. 2: Authorised operating conditions for the IPL-N/DPL-N series Supplementary installation and operating instructions ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 26 40 °C 40 °C 40 °C 7.5-10; no galvanised components) Water-glycol mixture Standard 2 and 4 40 °C 40 °C 40 °C 40 °C (20 %-40 % glycol) (AQ1EGG) Tab. 3: Authorised operating conditions for the IL/DL/BL series WILO SE 10/2013...
  • Page 27: Operation With Flammable Liquids And Explosion Protection

    • Machinery Directive (2006/42/EC) • Ordinance on Industrial Safety and Health (in accordance with Direc- tive 1999/92/EC) • Explosion Protection Ordinance (ExVO) • Hazardous Substances Ordinance (GefStoffV, in accordance with Directive 98/24/EC) Supplementary installation and operating instructions ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 28: Instructions Concerning Installation And Commissioning

    The coupling protection is to be remounted after the check has been completed. Electrical connection Wilo recommends using a motor protection apparatus as an additional protective device; this must be according to EN 60079 Part 14. Elec- trical installation in accordance with EN 60079 Part 14 is necessary in potentially explosive areas.
  • Page 29: Operating Instructions

    Supplementary installation and operating instructions ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 30 Danger of damage to the pump due to fluid temperatures which are too low! • It is a rule for pumps of the Wilo-VeroLine-IPS series that the min- imum temperature of the fluid is not permitted to fall below -10 °C, even with extreme ambient temperatures! 7.2.3 Operating mode of the pump...
  • Page 31 In any event, the operator of the system is responsible for complying with the defined fluid temperature (operating temperature). The maximum permitted temperature of the fluid is dependent on the Supplementary installation and operating instructions ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 32: Maintenance Instructions

    26 for renewed commissioning following completion of maintenance or repair work. All liability and warranties on the part of WILO SE are excluded for damages resulting from the use of non- original spare parts.The following special features are to be observed:...
  • Page 33: Motor Bearings

    The seal between pump housing and lantern is also to be replaced in any case. In the case of pumps of the Wilo-VeroLine- IPL-N or Wilo-VeroTwin- DPL-N series, an inspection should be made of the bore holes for flushing the mechanical seal to ensure that they are both unob- structed and clean at the time the seal is replaced.
  • Page 34 Modes d'utilisation non autorisés ........................42 Protection antidéflagrante ..........................42 Remarques sur l'entretien ........................45 Paliers de moteur ..............................46 Joints statiques ..............................46 Protection d'accouplement ..........................47 Garniture mécanique ............................47 Libre rotation de l'arbre d'entraînement ......................47 Roue de la gamme Wilo-VeroLine-IPS ......................47 WILO SE 10/2013...
  • Page 35: Généralités

    Signalisation des consignes de la notice Symboles Symbole général de danger Consignes relatives aux risques électriques Consigne de sécurité particulière relative à la protection anti- déflagrante REMARQUE Notice de montage et de mise en service complémentaire ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 36: Qualification Du Personnel

    être particulièrement respectés. Consignes de sécurité pour Les appareils Wilo ne sont pas prévus pour être utilisés par des personnes l'utilisateur (y compris des enfants) dont les capacités physiques, sensorielles ou mentales sont réduites, ou des personnes dénuées d'expérience ou de connaissance, sauf si elles ont pu bénéficier, par l'intermédiaire d'une...
  • Page 37: Consignes De Sécurité Pour Les Travaux De Montage Et D'entretien

    Des gaz, vapeurs ou liquides peuvent s'échapper de façon incontrôlée des garnitures d'étanchéité ou des raccords filetés. Notice de montage et de mise en service complémentaire ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 38: Transport Et Entreposage

    à la certification de vérification du moteur. Les pompes à moteur ventilé des gammes • Wilo-CronoLine-IL • Wilo-CronoTwin-DL • Wilo CronoBloc-BL • Wilo-VeroLine-IPL-N • Wilo-VeroTwin-DPL-N • Wilo-VeroLine-IPS sont prévues pour être utilisées en tant que circulateurs dans le génie du bâtiment.
  • Page 39: Informations Produits Et Conditions De Service

    Si cela n'est pas possible autrement, il convient d'installer un dispositif de surveillance du débit volumétrique. Notice de montage et de mise en service complémentaire ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 40: Conditions De Service Autorisées

    (pH : 7,5-10 ; aucun (AQ1EGG) 40 °C 40 °C composant galvanisé) Mélange eau/glycol Standard 2 et 4 40 °C 40 °C (20 % - 40 % glycol) (AQ1EGG) Tabl. 2 : Conditions de service autorisées pour les gammes IPL-N/DPL-N WILO SE 10/2013...
  • Page 41 40 °C 40 °C 40 °C 40 °C (20 % - 40 % glycol) (AQ1EGG) Tabl. 3 : Conditions de service autorisées pour les gammes IL/DL/BL Notice de montage et de mise en service complémentaire ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 42: Fonctionnement Avec Liquides Inflammables Et Protection Contre L'explosion

    • la directive sur les machines (2006/42/CE) • la réglementation sur la sécurité de fonctionnement (conformément à la directive 1999/92/CE) • la réglementation sur la protection contre l'explosion (ExVO) • la réglementation sur les substances dangereuses (GefStoffV, conformément à la directive 98/24/CE) WILO SE 10/2013...
  • Page 43: Remarques Sur Le Montage Et La Mise En Service

    140 °C ! Notice de montage et de mise en service complémentaire ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 44: Remarques Sur Le Fonctionnement

    Pour l'échappement d'air, en particulier lorsque des liquides présen- tant un danger pour les personnes ou l'environnement sont utilisés, un tuyau flexible doit être raccordé à la soupape d'évacuation d'air afin d'empêcher une évacuation incontrôlée du fluide dans l'environ- nement. WILO SE 10/2013...
  • Page 45 • Pour les pompes de la gamme Wilo-VeroLine-IPS, une température minimale du fluide de -10 °C ne doit pas être dépassée même en cas de températures ambiantes extrêmes ! Notice de montage et de mise en service complémentaire ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 46 • Les prescriptions des dispositifs de protection sont à respecter conformément à la norme EN 12100. 7.2.5 Bruit de la machine AVERTISSEMENT ! Risque de blessures corporelles ! En fonction des conditions locales, un niveau sonore permanent, qui provoque une nuisance sonore, peut se produire. WILO SE 10/2013...
  • Page 47: Remarques Sur L'entretien

    Notice de montage et de mise en service complémentaire ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 48: Paliers De Moteur

    Contrôler le bon fonctionnement des dispositifs de sécurité après achèvement des travaux d'entretien. Wilo recommande de faire appel à du personnel Wilo pour réaliser la première réparation sur la pompe. Le personnel d'entretien peut être en même temps formé. Wilo recommande en outre l'élaboration d'un programme d'entretien.
  • Page 49: Protection D'accouplement

    En raison du matériau utilisé, la roue de pompes de la gamme Wilo- Wilo-VeroLine-IPS VeroLine-IPS doit être remplacée après un temps de fonctionnement de 8 ans. Sous réserve de modifications techniques ! Notice de montage et de mise en service complémentaire ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 50 Testloop met product ............................57 Aanwijzingen bij het bedrijf .......................58 Ongeoorloofde gebruikswijzen ..........................58 Explosiebeveiliging ..............................58 Aanwijzingen voor het onderhoud ....................61 Motorlager ................................62 Statische afdichtingen ............................62 Koppelingsbeveiliging ............................62 Mechanische afdichting ............................62 Bewegingsvrijheid van de aandrijfas .........................63 Waaier van de serie Wilo-VeroLine-IPS ......................63 WILO SE 10/2013...
  • Page 51: Algemeen

    Voor de naleving hiervan – ook door het betrokken montagepersoneel - is de eindgebruiker verantwoordelijk. Neem contact op met de Service-International van WILO SE voor extra informatie of aanwijzingen en in geval van schade. Aanduiding van aanwijzingen in de...
  • Page 52: Personeelskwalificatie

    Veiligheidsaanwijzingen voor de Wilo-apparaten zijn niet bedoeld om gebruikt te worden door perso- gebruiker nen (kinderen inbegrepen) met verminderde fysieke, sensorische of geestelijke vermogens of een gebrek aan ervaring en/of kennis,...
  • Page 53: Veiligheidsvoorschriften Voor Montage- En Onderhoudswerkzaamheden

    Doordat de pomp in bedrijf is, bestaat – zoals bij alle circulatiepro- cessen met brandbare vloeistoffen – de mogelijkheid dat de gecir- Extra inbouw- en bedieningsvoorschriften ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 54: Transport En Opslag

    Vanwege de daarbij mogelijke toerentallen bestaat gevaar voor oververhitting en dus overschrijding van het toelaatbare tempera- tuurbereik. • De bedrijfsomstandigheden en de toegestane vloeistoffen zijn te vinden in het volgende hoofdstuk 5.2 ”Toegestane bedrijfsom- standigheden” op pagina 54 van deze inbouw- en bedieningsvoor- schriften. WILO SE 10/2013...
  • Page 55: Gegevens Over De Producten En Bedrijfsomstandigheden

    De pomp mag niet tegen gesloten ventielen, kleppen, schuiven of andere afsluitarmatuur in de kringloop van de media draaien. Als dit niet kan worden uitgesloten, moet er een bewaking voor de volumestroom worden geïnstalleerd. Extra inbouw- en bedieningsvoorschriften ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 56: Toegestane Bedrijfsomstandigheden

    Koelwater met antivries Standaard 2 en 4 (pH-waarde: 7,5-10; geen (AQ1EGG) 40 °C 40 °C verzinkte componenten) Water-glycol-mengsel Standaard 2 en 4 40 °C 40 °C (20 %-40 % glycol) (AQ1EGG) Tab. 2: Toegestane bedrijfsomstandigheden voor de serie IPL-N/DPL-N WILO SE 10/2013...
  • Page 57 40 °C verzinkte componenten) Water-glycol-mengsel Standaard 2 en 4 40 °C 40 °C 40 °C 40 °C (20 %-40 % glycol) (AQ1EGG) Tab. 3: Toegestane bedrijfsomstandigheden voor de serie IL/DL/BL Extra inbouw- en bedieningsvoorschriften ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 58: Bedrijf Met Brandbare Vloeistoffen En Explosiebeveiliging

    • technische regelgeving voor brandbare vloeistoffen (TRbF) • verordening voor elektrische en niet-elektrische apparaten in explo- siegevaarlijke ruimten (richtlijn 94/9/EG) • machinerichtlijn (2006/42/EG) • bedrijfsveiligheidsverordening (volgens richtlijn 1999/92/EG) • explosiebeveiligingsverordening (ExVO) • verordening voor gevaarlijke stoffen (GefStoffV, volgens richtlijn 98/ 24/EG) WILO SE 10/2013...
  • Page 59: Aanwijzingen Voor Opstelling En Inbedrijfname

    140°C kunnen voorkomen! De aanwijzingen in hoofdstuk 7.2.1 ”Vullen/ontluchten van de pomp” op pagina 58 moeten beslist in acht worden genomen! Extra inbouw- en bedieningsvoorschriften ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 60: Aanwijzingen Bij Het Bedrijf

    Vloeistoffen die schadelijk zijn voor mens en milieu kunnen bij aan- raking letsel en schade aan het milieu veroorzaken! • Ongecontroleerd vrijgekomen vloeistof moet met inachtneming van de wettelijke bepalingen worden afgevoerd. • Bij het ontluchten veiligheidskleding, veiligheidshandschoenen en veiligheidsbril dragen. WILO SE 10/2013...
  • Page 61 VOORZICHTIG! Gevaar voor materiële schade! Gevaar voor beschadiging van de pomp door te lage mediumtem- peraturen! • Voor pompen van de serie Wilo-VeroLine-IPS geldt dat de vloei- stoftemperatuur ook bij extreme omgevingstemperaturen niet onder de minimale vloeistoftemperatuur van -10°C mag komen! 7.2.3 Bedrijfssituatie van de pomp...
  • Page 62 Alleen als er originele reserveonderdelen worden gebruikt, kan de correcte werking van de pomp worden gegarandeerd. Bij onderde- len die niet van Wilo zijn, kan niet worden gegarandeerd dat hun constructie en productie aan de vereisten voor belasting en veilig- heid voldoen.
  • Page 63: Aanwijzingen Voor Het Onderhoud

    • Hoofdschakelaar afsluiten en sleutel eruit trekken • Een waarschuwingsbord tegen herinschakeling aanbrengen. • Veiligheidsvoorschriften voor de te transporteren vloeistof in acht nemen. • Het specificatieblad voor veiligheid raadplegen voor o.a. maatrege- len voor persoonlijke bescherming. Extra inbouw- en bedieningsvoorschriften ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 64: Motorlager

    Na beëindiging van de onderhoudswerkzaamheden dient te worden gecontroleerd of de veiligheidsinrichtingen goed werken. Wilo beveelt aan om bij reparaties aan de pomp die voor het eerst worden uitgevoerd Wilo-personeel in te schakelen. Uw onderhouds- personeel kan dan gelijktijdig worden geschoold. Ook beveelt Wilo de opstelling van een onderhoudsschema aan.
  • Page 65: Bewegingsvrijheid Van De Aandrijfas

    Waaier van de serie Vanwege het gebruikte materiaal dient bij pompen van de serie Wilo-VeroLine-IPS Wilo-VeroLine-IPS de waaier na een bedrijfstijd van 8 jaar te worden vervangen. Technische wijzigingen voorbehouden! Extra inbouw- en bedieningsvoorschriften ATEX Wilo-Crono... IL/DL/BL, Wilo-Vero... IPL-N/DPL-N, IPS...
  • Page 67  $OFDO– GH +HQDUHV =,3 &RGH  :,/2 9LHWQDP &R /WG  *DQJVHR %XVDQ 4050-040 Porto (Madrid) T +55 11 2923 (WILO) DE14 2WJ +R &KL 0LQK &LW\ 9LHWQDP T +351 22 2080350 T +34 91 8797100 9456 T +44 1283 523000...
  • Page 68 WILO SE Nortkirchenstraße 100 D-44263 Dortmund Germany T +49(0)231 4102-0 F +49(0)231 4102-7363 wilo@wilo.com Pioneering for You www.wilo.com...

Table of Contents