Wilo-Economy CO-1 ..., CO/T-1 ... .../CE+ .../ER
Wilo-Comfort-Vario COR-1 ... ...-GE .../VR
D
Einbau- und Betriebsanleitung
GB
Installation and operating instructions
F
Notice de montage et de mise en service
NL
Inbouw- en bedieningsvoorschriften

Advertisement

loading
Need help?

Need help?

Do you have a question about the Wilo-Economy CO-1/T-1 /CE+ /ER Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Wilo Wilo-Economy CO-1/T-1 /CE+ /ER Series

  • Page 1 Wilo-Economy CO-1 ..., CO/T-1 ../CE+ .../ER Wilo-Comfort-Vario COR-1 ..-GE .../VR Einbau- und Betriebsanleitung Notice de montage et de mise en service Installation and operating instructions Inbouw- en bedieningsvoorschriften...
  • Page 2 Fig. 1a Fig. 1b 11 15 Fig. 1c Fig. 1d...
  • Page 3 Fig. 1e Fig. 1f Fig. 1g...
  • Page 4 Fig. 2a Fig. 2b...
  • Page 5 Fig. 3a...
  • Page 6 Fig. 3b...
  • Page 7 Fig. 4 Fig. 5...
  • Page 8 Fig. 6a...
  • Page 9 Fig. 6b Fig. 7a Fig. 7b...
  • Page 10 Fig. 8...
  • Page 11 Fig. 9 Fig. 10a...
  • Page 12 Fig. 10b...
  • Page 13 Electrical connection ............................30 Commissioning/Decommissioning .....................30 General preparations and checking ........................30 Protection against low water level (WMS) ......................32 Commissioning the system ..........................32 Decommissioning the system ..........................32 Maintenance ............................33 Faults, causes and remedies .......................33 Spare parts ............................33 WILO SE 07/2010...
  • Page 14 English Captions: Installation and operating instructions Wilo Pressure boosting system s (DEA) Fig. 3b Pressure switch, type CS (normally closed contact) Fig. 1a Example CO-1HELIX V…../CE+ Adjusting screw for deactivation pressure Fig. 1b Example CO-1MVI…../ER (upper switching point) Adjusting screw for differential pressure Fig.
  • Page 15 Tank full, contact closed Lever rod Tank empty, contact open Float valve curve CO/T (11/4) m³/h Volume flow rate BN = Brown Inlet pressure BU = Blue BK = Black Contacts in the control device for low-water sig- nal transmitter WILO SE 07/2010...
  • Page 16 WARNING! The user can suffer (serious) injuries. 'Warning' implies that (serious) injury to persons is proba- ble if this information is disregarded. Installation and operating instructions Wilo-Economy CO-1, CO/T-1;-Comfort-Vario COR-1...
  • Page 17: Transport And Interim Storage

    Wilo range or a lugs or taken round the base frame. The pipes break tank provided independently by the cus- and fittings will not withstand loads and should tomer.
  • Page 18: Product Information

    Helix VE Pump series reference (see attached pump ration. documentation) Nominal volume flow Q Number of pump stages Number of reduced stages Control device, in this case the Vario Regler (controller) Installation and operating instructions Wilo-Economy CO-1, CO/T-1;-Comfort-Vario COR-1...
  • Page 19 (Fig. 3a) or pressure switch CS (Fig. 3b) switch (Fig. 9) is installed in the break tank as a • Draining/venting (17) signal transmitter for protection against low water • Stop valve (18) level. Water from the supply mains is fed into the WILO SE 07/2010...
  • Page 20 With systems of series (Fig. 2a) or a mechanical pressure switch (Fig. 2b) CO/T or if a Wilo break tank is used, a float switch depending on the type of control device. (Fig. 9) is already included in the supplied system.
  • Page 21: Installation

    +0 °C to 40 °C with a relative Accessories must be ordered separately if needed. atmospheric humidity of 50%. The accessories included in the Wilo range include • Installation and operation in the vicinity of living the following: rooms and bedrooms is not recommended.
  • Page 22 (Fig. 9). kept as low as possible (i.e. short pipe, few elbows • In the case of indirect connection via a Wilo and sufficiently large stop valves), otherwise the break tank, a float switch for level monitoring is...
  • Page 23 This means that the connection must be made using flexible components, like expansion joints or hoses. The tank overflow must be connected according to the regulations in force (in Germany, DIN 1988/part 3). Heat transmission through the WILO SE 07/2010...
  • Page 24 (sparks, radiated heat). The rubber able measures. PE tanks in the Wilo range are only parts of expansion joints must not be painted and designed to accommodate clean water. The max- must be protected from oil.
  • Page 25 We recommend that the initial commissioning of pressure fluctuations in the inlet pipe of more the system is performed by Wilo’s customer serv- than 1 bar or if the supply pressure fluctuation is ice. Contact your dealer, your nearest Wilo repre-...
  • Page 26 Contact 2 to Contact 4 (Fig. 3a, 26 and 27). After this connection is swapped around, the contact opens when pressure drops and closes when the target pressure is reached. Installation and operating instructions Wilo-Economy CO-1, CO/T-1;-Comfort-Vario COR-1...
  • Page 27 The protection against low water level (WMS) (Fig. 6a and 6b) for monitoring the supply pressure is permanently factory-set to the thresholds 1 bar (deactivates if pressure below this value) and 1.3 bar (starts up again when pressure goes above this value). WILO SE 07/2010...
  • Page 28: Maintenance

    (C, Fig. 4). (PN2 = pump switch-on pressure pmin less 0.2-0.5 bar or the value given in the table on the vessel (Fig. 5) - Wilo customer service). If the pressure is too high, discharge nitrogen at the valve. CAUTION!
  • Page 29: Eg-Konformitätserklärung

    2006/42/CE appendice II,1A et 2004/108/CE appendice IV,2) Hiermit erklären wir, dass die Bauart der Baureihe : Wilo-COE-1…n* /MVI/MVIS Herewith, we declare that the product type of the series: Par le présent, nous déclarons que l’agrégat de la série : (Die Seriennummer ist auf dem Typenschild des Produktes angegeben.
  • Page 30 2006/42/EC annex II,1A and2004/108/EC annex IV,2, conforme 2006/42/CE appendice II,1A et 2004/108/CE appendice IV,2) Hiermit erklären wir, dass die Bauart der Baureihe : Wilo Economy-CO-1 Helix V…/CE Herewith, we declare that the product type of the series: Wilo Comfort-N-CO-1…6 MVIS…/CC Par le présent, nous déclarons que l’agrégat de la série :...
  • Page 31 B'dan il-mezz, niddikjaraw li l-prodotti tas-serje jissodisfaw id- dispo izzjonijiet relevanti li Þejjin: Makkinarju - Direttiva 2006/42/KE L-objettivi tas-sigurta tad-Direttiva dwar il-VultaÞÞ Baxx huma konformi ÞÞ WILO SE WILO SE mal-Anness I, Nru 1.5.1 tad-Direttiva dwar il-Makkinarju 2006/42/KE. Nortkirchenstraße 100 Nortkirchenstraße 100...
  • Page 34 Lithuania Serbia and Montenegro Taiwan WILO SALMSON WILO Lietuva UAB WILO Hrvatska d.o.o. WILO Magyarország Kft WILO Beograd d.o.o. WILO-EMU Taiwan Co. Ltd. Argentina S.A. 03202 Vilnius 10090 Zagreb 2045 Törökbálint 11000 Beograd 110 Taipeh C1295ABI Ciudad T +370 5 2136495...
  • Page 35 Kommune Österreich WILO SE Bau + Bergbau Zentrale Wien: Argentinien, Aserbaidschan, Nortkirchenstraße 100 WILO EMU GmbH Industrie WILO Pumpen Österreich GmbH Belarus, Belgien, Bulgarien, 44263 Dortmund Heimgartenstraße 1 Eitnergasse 13 China, Dänemark, Estland, T 0231 4102-7516 95030 Hof WILO SE...