Wiring Connection - LG AB-Q24GM1A2 Installation Manual

Table of Contents

Advertisement

INSTALLATION OF INDOOR
10

Wiring Connection

• Open the control box cover and connect the
Remote controller wiring and Indoor power
wires.
• Remove the control box cover for electrical
connection between the indoor and outdoor
unit.
• Use the cord clamper to fix the wiring.
CAUTION
!
The power wiring connected to the out-
door unit should be complied with the fol-
lowing specifications (This equipment
shall be provided with a cord set comply-
ing with the national regulation).
NORMAL CROSS-SECTIONAL AREA
Capacity (kW)
5 / 7 / 10
13.4 / 15.8
The connecting wiring connected to the
indoor and outdoor unit should be com-
plied with the following specifications
(This equipment shall be provided with a
wiring set complying with the national
regulation).
NORMAL
CROSS-SECTIONAL
AREA 0.75 mm
If the supply wiring is damaged, it must
be replaced by a special wiring or assem-
bly available from the manufacturer of its
service agent.
AREA(mm
2
)
2.5
6.0
2
CAUTION
!
The Power cord connected to the unit
should be selected according to the fol-
lowing specifications.
Precautions when laying power wiring
Use round pressure terminals for connec-
tions to the power terminal block.
Round pressure terminal
When none are available, follow the in-
structions below.
• Do not connect wiring of different thick-
nesses to the power terminal block.
(Slack in the power wiring may cause
abnormal heat.)
• When connecting wiring which is the
same thickness, do as shown in the fig-
ure below.
WARNING
!
Make sure that the screws of the terminal
are free from looseness.
Power wiring

Advertisement

Table of Contents
loading