Wiring Connection - LG 1 Way Cassette ZTUQ12GULA1 Owner's Manual

Table of Contents

Advertisement

Wiring Connection

Electrical Wiring
Perform the electrical wiring work according to the
electrical wiring connection.
Circuit breaker detail
• All wiring must comply with local requirements.
• Select a power source that is capable of
supplying the current required by the air
conditioner.
• Use a recognized circuit breaker between the
power source and the unit.
A disconnect all supply lines must be fitted.
a
Main power source
b
Circuit breaker
c
Switch box
Indoor
d
Outdoor
e
• Capacity of circuit breaker
Model
Phase (Ø)
ZTUQ12GULA
1
ZTUQ18GTLA
1
ZTUQ24GTLA
1
ELCB
1
16 A
1
16A
1
25 A
Connecting Cable to the Indoor
Unit
NOTE
• The feature can be changed according to type of
model.
The power cord connected to the outdoor unit
should be with the following specifications
Normal Cross-Section Area
Model
Phase (Ø)
ZTUQ12GULA
1
ZTUQ18GTLA
1
ZTUQ24GTLA
1
INSTALLATION
Area (mm
1
1.5 (16AWG)
1
1.5 (16AWG)
1
2.5 (12AWG)
21