Standard Multi Label

When Standard Multi Label has been selected from the Code Combination drop-
down list, the Barcode Configuration window reveals related input fields.
In case of Multi Label, the codes will be distinguished EITHER by their symbology, OR by
their contents. If two (or more) codes share the same symbology and content, the scan-
ner will not perceive them as a unique code.
1. Enter the appropriate information in the form as described below:
Code Combination - Standard Multi Label has been selected.
No Read Message
Select Disable No Read Message, Global No Read Message, or Local No Read(s)
Message from the drop-down list. The No Read condition occurs whenever a code
cannot be read or decoded.
Disable No Read Message: The No Read Message is not transmitted.
Global No Read Message: The No Read String will be sent if the scanner is unable to
decode one or more barcodes in the reading phase.
Local No Read(s) Message: This option is useful when one or more codes are not
read in the reading phase or when more codes than the expected number set by
the configuration parameters are read.
If working in Standard Multi Label mode, this option activates the Code Label Local
No Read String and the Code Label Local Multiple Read String parameters which
allow setting a Local No Read String and a Local Multiple string in the Barcode
Settings Table for each defined code symbology.
Use 'Global No Read String' when No Codes Read
Select the check box to allow the Global No Read String to be used if no codes at all
are read. This option is not available when Global No Read Message is selected
from the No Read Message drop-down list.
Global No Read String (max. 128 chars)
Click
Global No Read Message is selected from the No Read Message drop-down list.
Click Submit to save your text to the origin window text field, or click Cancel to
return to origin window without transferring text.
These filter options are provided to eliminate false multiple reads.
Multiple Read Message
Select Disable or Enable from the drop-down list. This string will be sent if, during
the reading phase, the scanner reads more than the number of the expected
barcodes set by the configuration parameters. 
Reference Manual
to activate the Text Entry Tool and create a string to be displayed when
Standard Multi Label
83