PS Line
This parameter defines the read signal Y coordinate (mm) referred to the origin of
co-ordinates used for PackTrack™ configuration (see below).
Minimum Package Length
Enter the minimum length of a pack in the space provided (mm, in).
Minimum Distance Error Behavior
Select Ignore Error, Compose, or Discard Last from the drop-down list.
Minimum Distance Between Packages
Enter the minimum distance (mm, in) between consecutive packs. This field is only
available when Compose or Discard Last is selected for the Minimum Distance Error
Behavior.
Window Dimension
Enter a Window Dimension in the field provided.
The measurement of a barcode position in absolute coordinates performed by the
scanners may be affected by an error. PackTrack™ evaluation can fail in assigning
the barcode for this reason. With the Window Dimension parameter, the Y
coordinates that delimit the pack can be virtually extended to improve the
assigning success rate (see the following figure).
If the minimum distance between two consecutive packs is less than twice the value
of the Window Dimension, the window is dynamically resized (dynamic window) to
half the distance between the two packs. The code will be assigned within the
Window Dimension of the closest pack.
If the minimum distance between two consecutive packs is more than twice the
value of the Window Dimension, the code will be assigned within the Window
Dimension itself.
Reference Manual
Ignore Error: the occurred error is ignored
Compose: Enter the Minimum Distance Between Packs in the field provided.
Discard Last: discards all received packs
Operating Mode