SPECIFICATIONS
Motor:
420W
Max. Flow Rate:
1,900 l/h
Max. Lift:
0m
Max. Head:
33m
Inlet:
25.4mm (1"BSP) Female
Outlet:
25.4mm (1"BSP) Male
Water Temp.:
1oC to 35ºC
IP Rating:
IPX4
Weight:
6.95kg
ozito.com.au
IN ORDER TO MAKE A CLAIM UNDER THIS
WARRANTY YOU MUST RETURN THE PRODUCT
TO YOUR NEAREST BUNNINGS WAREHOUSE WITH
YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO
RETURNING YOUR PRODUCT FOR WARRANTY
PLEASE TELEPHONE OUR CUSTOMER SERVICE
HELPLINE:
Australia 1800 069 486
New Zealand 0508 069 486
TO ENSURE A SPEEDY RESPONSE PLEASE
HAVE THE MODEL NUMBER AND DATE OF
PURCHASE AVAILABLE. A CUSTOMER SERVICE
REPRESENTATIVE WILL TAKE YOUR CALL
AND ANSWER ANY QUESTIONS YOU MAY
HAVE RELATING TO THE WARRANTY POLICY
OR PROCEDURE.
OZITO
Australia/New Zealand (Head Office) 1-23 Letcon Drive, Bangholme, Victoria, Australia 3175.
WARRANTY
The benefits provided under this warranty are in addition
to other rights and remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded
at law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable
loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
Generally you will be responsible for all costs associated with
a claim under this warranty, however, where you have suffered
any additional direct loss as a result of a defective product you
may be able to claim such expenses by contacting our customer
service helpline above.
3 YEAR REPLACEMENT WARRANTY
Your product is guaranteed for a period of 36 months from
the original date of purchase. If a product is defective it will
be replaced in accordance with the terms of this warranty.
Warranty excludes consumable parts, for example: O-rings, bearing,
seals gaskets.
WARNING
The following actions will result in the warranty being void.
• If the tool has been operated on a supply voltage other
than that specified on the tool.
• If the tool shows signs of damage or defects caused
by or resulting from abuse, accidents or alterations.
• Failure to perform maintenance as set out within the
instruction manual.
• If the tool is disassembled or tampered with in any way.
• Professional, industrial or high frequency use.
WHAT'S IN THE BOX
Constant Pressure Pump
Teflon Tape
CPP-370
1017

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CPP-370 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ozito CPP-370

  • Page 1 IP Rating: IPX4 Weight: 6.95kg ozito.com.au CPP-370 WARRANTY IN ORDER TO MAKE A CLAIM UNDER THIS The benefits provided under this warranty are in addition WARRANTY YOU MUST RETURN THE PRODUCT to other rights and remedies which are available to you at law.
  • Page 2: Know Your Product

    KNOW YOUR PRODUCT SETUP & PREPARATION CONSTANT PRESSURE PUMP 1. SETTING UP 1. Discharge outlet 4. Pump body 2. Pump control unit 5. Suction inlet WARNING!: ENSURE THE PUMP IS DISCONNECTED 3. Control unit union 6. Base FROM THE POWER SUPPLY BEFORE PERFORMING ANY OF THE FOLLOWING OPERATIONS.
  • Page 3 The outlet allows for a 25.4mm (1”) delivery line to be connected and is capable of a maximum head of 33m Note: The Ozito TPIK-025 Tank to pump installation kit is available from Bunnings stores and may assist in your installation. 1. Remove the plastic protection cover from the discharge outlet.
  • Page 4: Installation

    A suction in-line filter with a 3000l/hour min flow rate, and 150 to DO NOT 250 micron mesh must be used to protect the pump from sand, dirt etc. The Ozito PAPF-001 Pre-filter or equivalent is available from Bunnings POTENTIAL FOR AIR ENTRAPMENT stores.
  • Page 5: Operation

    WARNING!: THIS PRODUCT IS INTENDED FOR PUMPING WATER IN A HOME DOMESTIC APPLICATION. DO NOT USE IT FOR CORROSIVE, ABRASIVE, EXPLOSIVE OR DANGEROUS LIQUIDS. Note: IPX4 - pump can handle splashing of water with no harmful effect. CPP-370...
  • Page 6: Maintenance

    MAINTENANCE OPERATION (cont.) WARNING! MAKE SURE THE PUMP IS DISCONNECTED FROM ELECTRIC POWER SUPPLY BEFORE 8. OPERATING THE PUMP PERFORMING MAINTENANCE PROCEDURES. Pump Control Unit WARNING! MAKE SURE THAT THE DEVICE AND CONNECTED ACCESSORIES ARE DEPRESSURIZED BEFORE CARRYING OUT ANY WORK ON THE DEVICE. ‘GREEN Power on’.
  • Page 7: Troubleshooting

    Spare parts can be ordered from the Special Orders Desk at your local Bunnings Warehouse. For further information, or any parts not listed here, visit www.ozito.com.au or contact Ozito Customer Service: Australia 1800 069 486 New Zealand 0508 069 486...
  • Page 8: Electrical Safety

    Before use, inspect the extension lead for signs of damage, wear and ageing. Replace the Note: The supply of 230V and 240V on Ozito pumps are interchangeable for Australia and extension lead if damaged or defective. Then using an extension lead on a reel, always New Zealand.