Vivotek IB9367-EHT-v2 User Manual page 407

2mp, outdoor, ip66, ik10, day & night, smart vca, wdr pro, smart stream iii; 50m smart ir
Table of Contents

Advertisement

© 2020 VIVOTEK INC. All Right Reserved
PARAMETER
VALUE
function
focus,
auto,
scan,
stop,
positioning,
irisopen,
irisenable,
resetfocus
direction
direct,
forward,
backward
position
<motor_start> ~
<motor_end>
steps
1 ~ 30
iris
N/A
(for query API)
Syntax:
http://<servername>/cgi-bin/admin/remotefocus.cgi?channel=<value>&[function=<value>]
DESCRIPTION
focus – Move focus motor
auto – Perform auto focus
scan – Perform focus scan
stop – Stop current operation
positioning – Position the motors
resetfocus – reset focus position to default
irisopen – Fully open iris. It will maintain fully open iris
status until sending function=irisenable cgi.
irisenable – return back to user setting status of iris.
Motor's moving direction.
It works only if function= focus.
Motor's position.
It works only if function=focus and direction=direct.
<motor_start> : remote_focus_zoom_motor_start or
remote_focus_focus_motor_start,
<motor_end> : remote_focus_zoom_motor_end or
remote_focus_focus_motor_end replied from
"function=getstatus"
Motor's moving steps.
It works only if function=focus and direction=forward or
direction=backward.
* Motor will stop when it reaches to <motor_start> or
<motor_end>.
* This parameter is for additional fine-tune, the value is from 1
to 30.
Open iris or not.
It works only if function=auto or function=scan.
VIVOTEK
268
User's Manual - 407

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fd9367-ehtv-v2

Table of Contents