Connector
Pin
1
GND
YC4
Connected to
2
BRIDGE_SENS 2
the bridge
3
+5V
conveying
sensor 2
1
GND
YC6
Connected to
2
BRIDGE_SENS 1
the bridge
3
+5V
conveying
4
GND
sensor 2 and
5
BRIDGE_OPEN
bridge cover
switch
6
+5V
7
NC
YC7
1
BRIDGE1_B/
2
BRIDGE1_A/
Connected to
the bridge
3
BRIDGE1_B
conveying
4
BRIDGE1_A
motor1,2
5
BRIDGE2_B/
6
BRIDGE2_A/
7
BRIDGE2_B
8
BRIDGE2_A
All manuals and user guides at all-guides.com
Signal
I/O
Voltage
-
-
I
0/5V DC
O
5V DC
-
-
I
0/5V DC
O
5V DC
-
-
I
0/5V DC
O
5V DC
-
-
O
0/24V DC(pulse)
O
0/24V DC(pulse)
O
0/24V DC(pulse)
O
0/24V DC(pulse)
O
0/24V DC(pulse)
O
0/24V DC(pulse)
O
0/24V DC(pulse)
O
0/24V DC(pulse)
2-3-7
3NC/3NB/3NK
Description
Ground
BRCM2: On/Off
5 V DC power output to BRCS2
Ground
BRCS1: On/Off
5 V DC power output to BRCS1
Ground
BRCUSW: On/Off
5 V DC power output to BRCUSW
Not used
BRCM1 control signal
BRCM1 control signal
BRCM1 control signal
BRCM1 control signal
BRCM2 control signal
BRCM2 control signal
BRCM2 control signal
BRCM2 control signal