20.2 Heat Mode Performance Data

Unit setting: Standard piping length, Hi Fan, Heat mode at 30°C Voltage: 230-240V
20.2.1
CS-Z25UD3RAW CU-Z25UBRA
Indoor (°C)
-15
DB
TC
IP
24
1568
714
20
1651
704
16
1333
687
20.2.2
CS-Z35UD3RAW CU-Z35UBRA
Indoor (°C)
-15
DB
TC
IP
24
1562
657
20
1671
622
16
1785
625
20.2.3
CS-Z50UD3RAW CU-Z50UBRA
Indoor (°C)
-15
DB
TC
IP
24
2547
1258
20
2684
1266
16
2969
1259
20.2.4
CS-Z60UD3RAW CU-Z60UBRA
Indoor (°C)
-15
DB
TC
IP
24
2922
1618
20
3080
1628
16
3407
1619
TC - Total Heating Capacity (W)
IP
- Input Power (W)
-7
TC
IP
TC
1973
724
2337
2110
721
2404
2168
714
2600
-7
TC
IP
TC
1950
714
2740
2068
681
3161
2164
644
2966
-7
TC
IP
TC
3219
1291
3886
3478
1338
3921
3588
1316
4252
-7
TC
IP
TC
3694
1659
4459
3991
1721
4499
4117
1692
4879
Outdoor WB (°C)
2
7
IP
TC
IP
726
3313
786
712
3300
780
718
3542
800
Outdoor WB (°C)
2
7
IP
TC
IP
755
3789
1033
830
4200
1030
745
4330
972
Outdoor WB (°C)
2
7
IP
TC
IP
1353
5446
1531
1294
6100
1680
1356
6282
1628
Outdoor WB (°C)
2
7
IP
TC
IP
1740
6250
1968
1664
7000
2160
1743
7209
2093
140
12
TC
IP
TC
3598
810
3632
3803
792
3669
3710
778
3922
12
TC
IP
TC
3813
822
3850
4374
1016
4220
4629
1023
4894
12
TC
IP
TC
5520
1382
5207
6653
1730
5624
7034
1725
6345
12
TC
IP
TC
6334
1777
5975
7635
2224
6454
8071
2217
7281
24
IP
635
549
777
24
IP
834
725
944
24
IP
1312
1177
1275
24
IP
1687
1514
1639