Adjusting the minimum setting for LPG
Tighten the screw located at the side of the
tap rod clockwise all the way.
Following adjustment to a gas
other than the one originally set in
the factory, replace the gas setting
label on the appliance with the
one corresponding to the new gas.
The label is inserted inside the
nozzle pack (where present).
Burner and nozzle specifications tables
NG 1.0 kPA
Nominal gas consumption (MJ/h)
Injector (1/100 mm)
Primary air (mm)
ULPG 2.75 kPa
Nominal gas consumption (MJ/h)
Injector (1/100 mm)
Primary air (mm)
Installation
Lubricating the gas cocks
Over time the gas taps may become difficult
to turn and get blocked. Clean them
internally and replace the lubrication
grease.
Lubrication of the gas taps should
be performed by a specialised
technician.
AUX
SR
4.3
6.1
0.95
1.10
4
3
AUX
SR
4.3
6.1
0.54
0.67
10
10
RR
R
UR
9.3
10.4
15.1
1.35
1.50
1.80
2
5
4
RR
R
UR
9.3
11.0
15.1
0.82
0.92
1.05
10
10
10
UR*
21.6
2.20
4
UR*
21.6
1.25
10
27