Download Print this page
NuTone NM200 Series Quick Start Manual

NuTone NM200 Series Quick Start Manual

Advertisement

Quick Links

Nm200 series
system iNstAllAtioN
reAd ANd sAve tHese iNstructioNs
cAutioN
to reduce tHe risk of fire, electric sHock, or
iNjury to persoNs, observe tHe folloWiNg:
1. Read all instructions carefully before installing or using the
NM200 System.
2. The NM200 must be installed by a qualified dealer or installer,
and must conform to all local building and electrical codes.
3. For continued protection against risk of fire replace the fuse
in the power switch module only with the same type 3 Amp,
250 Volt fuse.
4. Adhere to all warnings on the NM200 and in these instructions.
Follow all operating and installation instructions.
WArNiNg
tHese iNstAllAtioN ANd serviciNg iNstructioNs
Are for use by quAlified persoNNel oNly. to
reduce tHe risk of electric sHock, do Not
perform ANy serviciNg otHer tHAN tHAt coNtAiNed
iN tHe operAtiNg iNstructioNs uNless you Are
quAlified to do so.
• Do not attempt to service the NM200 yourself as opening
or removing covers may expose you to dangerous voltage
or other hazards. Refer all servicing to qualified service
personnel.
The lightning flash with arrowhead symbol within an
equilateral triangle is intended to alert the user to the
presence of uninsulated "dangerous voltage" within the
product's enclosure that may be of sufficient magnitude to
constitute a risk of shock to persons.
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the
literature accompanying the product.
• Locate the system away from heat sources such as radiators,
heat registers, stoves, or other heat producing products.
• Do not locate the NM200 master or remote stations in an
outside wall.
• Do not locate the NM200 to moisture. Doing so can create
fire or shock hazards and void the warranty.
• Do not place the NM200 master or remote stations in any
wall cavity with any other electrical wiring in the cavity.
• Install the NM200 system after the application of the wall
covering material.
• Do not expose the outdoor remote station speakers to
significant water contact. The outdoor remote speakers are
weatherproof but not water proof. Continuous direct water
exposure will cause system problems.
models Nm
• Do not connect CAT5 wire if you are unsure of its termination
point. Connecting a door station to a remote station may
result in system damage.
• Do ensure that all rough-in instructions have been followed
before power is applied to the NM200 system.
• Do not splice cables. Splices are unreliable and defeat signal
isolation properties of the cable.
• Do not attach devices unauthorized for use with this system.
Authorized devices include:
Audio components connected via a line level input
NC300 6-disc CD player
• If extra cables have been run for future speaker additions,
care must be taken to ensure these cables are not connected
to the NM200 master unit. Un-terminated cables (no station)
connected to the NM200 master may cause electronic
feedback that will damage the master unit.
• Do not over-tighten the screws for the remote stations or the
master as the plastic face panels may crack or strip out.
• Use only NuTone certified replacement parts and have them
installed by a qualified dealer or installer. Unauthorized
substitutions can result in fire, electric shock, or other
hazards.
• Upon completion of any service or product repair, have
the dealer or installer conduct a safety check to ensure the
system is in proper operating condition.
• Use only a damp cloth to clean the NM200 master and remote
stations. Do not use liquid cleaners or aerosol cleaners.
iNstAllAtioN
To ensure that the homeowner receives the high-quality music
and voice reproduction that the system is designed to deliver, it
is important that each step of the installation be done carefully.
In the event you need troubleshooting assistance, please call
our technical staff at 1-888-336-6151.
The installation should be made after the application of wall
covering material.
Tools required:
• #2 Phillips screwdriver
• Standard flat head screwdriver
• Wire stripper/cutter
• Level
iNstAlliNg tHe remote stAtioNs
Collect all the connectors included in the remote station packages
and place them in the master rough-in for use later. At each
remote station location, strip approximately 4 inches of jacket
200
200
WH • Nm
Al
Page 

Advertisement

loading

Summary of Contents for NuTone NM200 Series

  • Page 1 Nm WH • Nm Page  Nm200 series system iNstAllAtioN reAd ANd sAve tHese iNstructioNs cAutioN • Do not connect CAT5 wire if you are unsure of its termination point. Connecting a door station to a remote station may result in system damage. to reduce tHe risk of fire, electric sHock, or • Do ensure that all rough-in instructions have been followed...
  • Page 2 Audio WAll plAte Use the labels provided to mark respective cables. Connect the cables to the IA30WH audio wall plate and mount the plate using the two screws provided. Please see figure below and refer to the NuTone IA30WH installation guide for more detailed instructions. Nps200WH outdoor remote station At each outdoor remote station location, strip approximately 4 inches of jacket from the CAT5 wire and separate the colored conductors. Strip ½ inch of insulation from each conductor and...
  • Page 3 models Nm WH • Nm Page  Nm200 mAster stAtioN iNstAllAtioN Gather all remote station and door station cables and cut cable ends to the same length approximately 12 inches from entry point into master rough-in. Make sure that all cables remain properly labeled. Strip approximately 2” of jacket from each of the CAT5 cables. Untwist the individual wire pairs. Insert each wire pair into the correct connector location and close connector. Please see figure below. Insert each cable connector into its proper location on the NM200 master.
  • Page 4: Antenna Connection

    models Nm WH • Nm Page  Antenna connection poWeriNg up tHe Nm200 After all connections have been made, insert the power plug into Connect the FM dipole coax antenna lead “F” connector to the the transformer and secure the master to the rough-in using the FM 75 Ohm “F” connector on the NM200 master as shown in the 2 screws provided. If using the NF200C frame with a NC300 previous figure. Connect the orange AM antenna wire to the AM CD player, install the master unit over the frame. Do not over terminal on the master. tighten the screws as the plastic may distort or crack. Install the speaker panel on the master. door release connection Please be careful to only apply pressure on the speaker panel at the corners and not in the middle. Check all functions by To use the door release, connect the 18 gauge low volt- following the guidelines in the Owners Manual shipped with age cables from the remote power transformer and the door...
  • Page 5 Ud.puede tener otros derechos, los cuales varían de estado a estado. Esta garantias reemplaza a todas las garantías anteriores.. SERVICO DE GARANTÍA: Para tener derecho al servicio de garantía, Ud. debe (a) Notificar a Broan-NuTone a la dirección o el número de teléfono abajo, (b) indicar el número de modelo y la identifación de la party y (c) describir la naturaleza de cualquier defecto en la producto o parte.

This manual is also suitable for:

Nm200whNm200alNm200k