Nm200 mAster stAtioN iNstAllAtioN
Gather all remote station and door station cables and cut cable
ends to the same length approximately 12 inches from entry
point into master rough-in. Make sure that all cables remain
properly labeled. Strip approximately 2" of jacket from each of
the CAT5 cables. Untwist the individual wire pairs. Insert each
wire pair into the correct connector location and close connector.
Please see figure below. Insert each cable connector into its
proper location on the NM200 master.
Make sure that the outdoor remote station is connected into
the outdoor remote stations cables location only. If you are
connecting two outdoor remote stations, use the screw terminal
connectors provided with the NPS200 for the outdoor remote
station. Connect both outdoor remote stations cables into one
screw terminal connector.
it is important to verify all cable run locations prior
to connecting if they were not labeled at the rough-
in.
incorrectly connecting cables to the master,
remote stations or door stations may result in system
damage.
Mounting the Chime Module
Install the optional NA3003C or NA3008C chime module in the
master rough-in by pressing the chime module over the 4 plastic
standoffs attached to the rough-in as shown. Please refer to the
Suspend the master unit from the master rough-in by looping the
support wire assembly (thick green wire) over the hook at the
top of the rough-in. Be careful not to damage the wall surface.
models Nm
If the NM200 system has more than 9 remote stations, some
station selector switches will control two remote stations. Do
not exceed more than 15 total speakers on the system. This
limitation does not include door stations. The station location
can be noted on the inside of the front access panel on the left
side of the NM200 master.
Connect the red and black wires of the door station cables to the
red and black door speaker terminals on the NM200 master as
shown below. Insulate the bare wires using some of the jacket
material to prevent shorting to the circuit board. Connect this
wire to terminal labeled shield.
Connect all orange wires from the door stations to the common
terminal on the NA3003C or NA3008C.
Connect each yellow wire to a note selection terminal on the
NA3003C or NA3008C. Do not connect more than one yellow
wire per note terminal.
Plug in the modular chime plug to the 4 pin connector labeled as
CHIME on the NM200 master unit as shown.