5 Operation
2
Malfunctioning
Room
Main zone
Additional zone
Space heating/cooling
a
Selected submenu
Possible actions on this screen
Go through the list.
Enter the submenu.
Enable/disable breadcrumbs.
Submenu
[0]
Restriction: Only displayed if a
or
malfunction occurs.
Malfunctioning
See
case of a
information.
[1]
Restriction: Only displayed if a
Room
dedicated Human Comfort Interface
(BRC1HHDA used as room
thermostat) is controlling the outdoor
unit.
Set the room temperature.
[2]
Shows the applicable symbol for your
Main zone
main zone emitter type.
Set the leaving water temperature for
the main zone.
[3]
Additional zone Restriction: Only displayed if there
are two leaving water temperature
zones. Shows the applicable symbol
for your additional zone emitter type.
Set the leaving water temperature for
the additional zone (if present).
[4]
Shows the applicable symbol of your
Space heating/
unit.
cooling
Put the unit in heating mode or cooling
mode. You cannot change the mode
on cooling only models.
[7]
Gives access to user settings such as
User settings
holiday mode and quiet mode.
[8]
Displays data and information about
Information
the outdoor unit.
[9]
Restriction: Only for the installer.
Installer
settings
Gives access to advanced settings.
[A]
Restriction: Only for the installer.
Commissioning
Perform tests and maintenance.
[B]
Change the active user profile.
User profile
[C]
Turn heating/cooling functionality on or
Operation
off.
[D]
Restriction: Only displayed if a
Wireless
wireless LAN (WLAN) is installed.
gateway
Contains settings needed when
configuring the ONECTA app.
5.3.3

Setpoint screen

The setpoint screen is displayed for screens describing system
components that need a setpoint value.
Operation manual
10
a
Description
"8.1 To display the help text in
malfunction" [ 4  17] for more
Examples
[1] Room temperature screen
1
+
21
°C
Room
[3] Additional zone screen
3
+
12
°C
Additional zone
Explanation
d
+
c
a2
b2
e
d
d
e
a1
b1
Possible actions on this screen
Go through the list of the submenu.
Go to the submenu.
Adjust and automatically apply the desired
temperature.
Item
Minimum temperature limit
Maximum temperature limit
Current temperature
Desired temperature
Submenu
5.3.4

Detailed screen with values

a
c
b
a
Settings
b
Values
c
Selected setting and value
Possible actions on this screen
Go through the list of settings.
Change the value.
Go to the next setting.
Confirm changes and proceed.
[2] Main zone screen
2
+
20
°C
Main zone
Description
a1
Fixed by the unit
a2
Restricted by the installer
b1 Fixed by the unit
b2 Restricted by the installer
c
Measured by the unit
d
Turn the right dial to
increase/decrease.
e
Turn or press the left dial to
go to the submenu.
Example:
7.2.1
Time/date
Hours
11
30
Minutes
a
c
b