Daikin EWAA011-016DAV3P Operation Manual

Packaged air-cooled water chillers and packaged air to water heat pumps
Hide thumbs Also See for EWAA011-016DAV3P:

Advertisement

Quick Links

Operation manual
Packaged air-cooled water chillers
and packaged air to water heat pumps
EWAA011~016DAV3P
EWAA011~016DAW1P
EWAA011~016DAV3P-H-
EWAA011~016DAW1P-H-
EWYA009~016DAV3P
EWYA009~016DAW1P
Operation manual
EWYA009~016DAV3P-H-
Packaged air-cooled water chillers
English
EWYA009~016DAW1P-H-
and packaged air to water heat pumps

Advertisement

Table of Contents
loading

Summary of Contents for Daikin EWAA011-016DAV3P

  • Page 1 Operation manual Packaged air-cooled water chillers and packaged air to water heat pumps EWAA011~016DAV3P EWAA011~016DAW1P EWAA011~016DAV3P-H- EWAA011~016DAW1P-H- EWYA009~016DAV3P EWYA009~016DAW1P Operation manual EWYA009~016DAV3P-H- Packaged air-cooled water chillers English EWYA009~016DAW1P-H- and packaged air to water heat pumps...
  • Page 2: Table Of Contents

    Latest revisions of the supplied documentation may be available on 5.8.4 Using weather-dependent curves ....... 14 the regional Daikin website or via your installer. 6 Energy saving tips The original documentation is written in English. All other languages 7 Maintenance and service are translations.
  • Page 3: User Safety Instructions

    2 User safety instructions 1 Starting from the home screen, turn the left dial and CAUTION go to Space heating/cooling. ▪ Do NOT place any objects or equipment on top of the unit. ▪ Do NOT sit, climb or stand on the Space heating/cooling unit.
  • Page 4: About The System

    3 About the system ▪ Do NOT use cleaning materials or Components in a typical system layout means to accelerate the defrosting process other than those recommended by the manufacturer. ▪ Be aware that the refrigerant inside the system is odourless. WARNING The refrigerant inside the unit is mildly flammable, but normally does NOT...
  • Page 5: Space Heating/Cooling

    4 Quick guide 1 Go to [2]: Main zone or [3]: Additional zone. Advanced user 1234 Main zone Space heating/cooling To turn space heating/cooling operation ON or OFF Additional zone NOTICE Room frost protection. Even if you turn OFF space heating/cooling operation ([C.2]: Operation >...
  • Page 6: Operation

    With the WLAN cartridge, the installer can connect the system to the WD curve before changes WD curve after changes internet. As user you can then control the system via the Daikin Slope Residential Controller app. Note: This slot cannot be used for SD Offset cards.
  • Page 7: Menu Structure: Overview User Settings

    5 Operation Menu structure: Overview user settings Room Schedule Heating schedule Cooling schedule Antifrost [1.4] Antifrost Setpoint range Room sensor offset Activation Room comfort setpoint Room setpoint [1.5] Setpoint range Heating minimum Main zone Heating maximum Cooling minimum Schedule Cooling maximum Heating schedule Cooling schedule [1.9]...
  • Page 8: Possible Screens: Overview

    5 Operation Possible screens: Overview Item Description c Smart energy The most common screens are as follows: Smart energy is available via solar panels or smart grid. Smart energy is currently being used for space heating. d Space operation mode Cooling Heating e Outdoor / quiet mode...
  • Page 9: Setpoint Screen

    LAN (WLAN) is installed. gateway Values Selected setting and value Contains settings needed when Possible actions on this screen configuring the Daikin Residential Controller app. Go through the list of settings. Change the value. 5.3.3 Setpoint screen Go to the next setting.
  • Page 10: Turning Operation On Or Off

    5 Operation Turning operation ON or OFF In menu… You can read out… [8.6] Operation modes Current operation mode 5.4.1 Visual indication Example: Defrost/oil return mode Certain functionalities of the unit can be enabled or disabled [8.7] About Version information about the separately.
  • Page 11: To Change The Desired Leaving Water Temperature

    5 Operation 1 Go to [1]: Room. 2 Adjust the desired leaving water temperature. Room °C – Main zone 2 Adjust the desired room temperature. °C °C – – Room Additional zone a Actual room temperature a Actual leaving water temperature b Desired room temperature b Desired leaving water temperature If scheduling is on after changing the desired room temperature...
  • Page 12 5 Operation To copy the schedule to the other weekdays 2 Select Delete. 1 Select Monday. User defined 1 Delete Rename Select 3 Select OK to confirm. 2 Select Copy. To clear the content of a day schedule 1 Select the day of which you want to clear the content.
  • Page 13: Weather-Dependent Curve

    5 Operation ▪ 2-points curve 7 Select Sunday. 8 Select Paste. ▪ Slope-offset curve Which type of curve you use to make adjustments, depends on your Result: personal preference. "5.8.4  Using weather-dependent User defined 1 curves" [ 4  14]. Availability The weather-dependent curve is available for: ▪...
  • Page 14: Using Weather-Dependent Curves

    5 Operation general fine but at low ambient temperatures too cold, raise the Possible actions on this screen slope so that leaving water temperature is heated increasingly Select slope or offset. more at decreasingly lower ambient temperatures. Increase or decrease the slope/offset. ▪...
  • Page 15: Energy Saving Tips

    6 Energy saving tips ▪ Keep the area around the unit clean. You feel … Fine-tune with slope and offset: ▪ Keep the user interface clean with a soft damp cloth. Do NOT use At regular outdoor At cold outdoor Slope Offset any detergents.
  • Page 16: To Check The Malfunction History

    8 Troubleshooting ▪ When Emergency is set to auto SH reduced/DHW off (or auto ▪ : Error SH reduced/DHW on) and a heat pump failure occurs, space ▪ : Malfunction heating is reduced. You can get a short and a long description of the malfunction as Similarly as in Manual mode, the unit can take the full load with follows: backup...
  • Page 17: Disposal

    9 Disposal Disposal NOTICE Do NOT try to dismantle the system yourself: dismantling of the system, treatment of the refrigerant, oil and other parts MUST comply with applicable legislation. Units MUST be treated at a specialised treatment facility for reuse, recycling and recovery. Installer settings: Tables to be filled in by installer 10.1...
  • Page 20 4P620244-1 B 0000000W 4P620244-1B 2021.02 Verantwortung für Energie und Umwelt...

Table of Contents